Noninvasive coronary flow reserve assessed by transthoracic coronary Doppler ultrasound in patients with left anterior descending coronary artery stents.

Francesco Pizzuto1, Paolo Voci, Enrica Mariano, Paolo Emilio Puddu, Pier Andrea Chiavari, Francesco Romeo.   

Abstract

Noninvasive measurement of coronary flow reserve (CFR) (hyperemic/flow velocity ratio at rest) by transthoracic Doppler echocardiography showed normalization of flow in the left anterior descending (LAD) coronary artery early after stenting. We hypothesized that noninvasive CFR may reveal in-stent restenosis at follow-up. Therefore, we studied 134 patients, 0 to 72 months after successful proximal-middle LAD stenting, and 38 controls. LAD flow velocity was measured by transthoracic Doppler echocardiography during 90 seconds venous adenosine infusion (140 microg/kg/min). CFR was measured in diastole. According to angiography, patients who received stents were divided into 3 groups: group I, <50% LAD in-stent restenosis (n = 83); group II, nonsignificant (50% to 69%) LAD in-stent restenosis (n = 17); and group III, significant (> or = 70%) LAD in-stent restenosis (n = 34). LAD CFR was similar in group I and controls (2.90 +/- 0.58 vs 3.05 +/- 0.81; p = NS), it was slightly lower in group II (2.42 +/- 0.33) compared with controls and group I (p <0.001 vs both), and clearly abnormal (<2) in group III (1.38 +/- 0.48) compared with controls, and groups I and II (p <0.001). A CFR <2 had 91% sensitivity, 95% specificity, and 96% positive and 97% negative predictive values to detect significant stenosis in patients with LAD stents. Our data show that noninvasive Doppler assessment of CFR allows identification of significant LAD in-stent restenosis, based on a cut-off value of <2.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12615253     DOI: 10.1016/s0002-9149(02)03298-8

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  10 in total

1.  Evaluation of the coronary circulation and calcification in children on regular hemodialysis.

Authors:  Mohammed Al-Biltagi; Maher Ahmed Abd ElHafez; Doaa Mohamed El Amrousy; Mohamed El-Gamasy; Hesham El-Serogy
Journal:  Pediatr Nephrol       Date:  2017-05-11       Impact factor: 3.714

2.  Coronary flow velocity reserve is impaired in hypertensive patients with hyperhomocysteinemia.

Authors:  J Liu; Y Xu; H Zhang; X Gao; H Fan; G Wang
Journal:  J Hum Hypertens       Date:  2014-03-27       Impact factor: 3.012

Review 3.  Noninvasive assessment of coronary blood flow by transthoracic Doppler echocardiography: basic to practical use in the emergency room.

Authors:  Nozomi Watanabe
Journal:  J Echocardiogr       Date:  2017-01-23

Review 4.  Emerging, noninvasive surrogate markers of atherosclerosis.

Authors:  Samir N Patel; Venkataraman Rajaram; Sanjay Pandya; Benjamin M Fiedler; Charlotte J Bai; Rachel Neems; Matt Feinstein; Marshall Goldin; Steven B Feinstein
Journal:  Curr Atheroscler Rep       Date:  2004-01       Impact factor: 5.113

Review 5.  Coronary flow reserve in stress-echo lab. From pathophysiologic toy to diagnostic tool.

Authors:  Fausto Rigo
Journal:  Cardiovasc Ultrasound       Date:  2005-03-25       Impact factor: 2.062

6.  Feasibility of 3D4D echocardiography for the detection of colour-coded flow in the left anterior descending artery.

Authors:  Stephan Stoebe; Dietrich Pfeiffer; Andreas Hagendorff
Journal:  Echo Res Pract       Date:  2014-07-23

7.  Feasibility of proximal right coronary artery imaging by 2D and 3D echocardiography in comparison to coronary angiography.

Authors:  Stephan Stoebe; Katharina Lange; Dietrich Pfeiffer; Andreas Hagendorff
Journal:  Echo Res Pract       Date:  2015-05-29

8.  Distal left circumflex coronary artery flow reserve recorded by transthoracic Doppler echocardiography: a comparison with Doppler-wire.

Authors:  Antonio Auriti; Christian Pristipino; Cinzia Cianfrocca; Antonino Granatelli; Vincenzo Guido; Francesco Pelliccia; Salvatore Greco; Giuseppe Richichi; Massimo Santini
Journal:  Cardiovasc Ultrasound       Date:  2007-06-16       Impact factor: 2.062

Review 9.  Transthoracic Doppler echocardiography - noninvasive diagnostic window for coronary flow reserve assessment.

Authors:  Paweł Petkow Dimitrow
Journal:  Cardiovasc Ultrasound       Date:  2003-04-11       Impact factor: 2.062

10.  Usefulness of coronary flow reserve measured by transthoracic coronary Doppler ultrasound in the elderly.

Authors:  Danijela Trifunovic; Edina Cenko; Concetta Torromeo; Beatrice Ricci; Michele Schiariti; Marija Zdravkovic; Zorana Vasiljevic; Olivia Manfrini
Journal:  J Geriatr Cardiol       Date:  2017-07       Impact factor: 3.327

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.