Literature DB >> 12612465

Comparison of 99mTc-sestamibi-18F-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress 99mTc-sestamibi single photon emission computed tomography for the assessment of myocardial viability.

J De Boer1, R H J A Slart, P K Blanksma, A T M Willemsen, P L Jager, A M J Paans, W Vaalburg, D A Piers.   

Abstract

Dual isotope simultaneous acquisition single photon emission computed tomography (DISA SPECT) offers the advantage of obtaining information on myocardial perfusion using Tc-sestamibi ( Tc-MIBI) and metabolism using F-fluorodeoxyglucose ( F-FDG) in a single study. The prerequisite is that the Tc-MIBI images are not degraded by scattered 511 keV photons or poor count statistics due to the lower efficiency of the extra high energy (EHE) collimator. Therefore, we compared the registered Tc-MIBI uptake and image quality of DISA and single isotope acquisition. Furthermore, we investigated whether DISA yields additional information for the assessment of myocardial viability in comparison with rest-stress Tc-MIBI. Nineteen patients with known coronary artery disease and irreversible perfusion defects on previous rest-stress MIBI test studies were investigated. After oral glucose loading and simultaneous injection of 600 MBq of Tc-MIBI and 185 MBq of F-FDG at rest, DISA was performed using energy windows of 140 (+/-15%), 170 (+/-20%) and 511 keV (+/-15%). Planar 140 keV images were corrected for scatter by subtraction using the 170 keV window. The single and dual isotope Tc-MIBI images were both displayed in a polar map with 128 segments normalized to maximum counts. F-FDG and Tc-MIBI images were visually scored for a perfusion-metabolism mismatch pattern using nine regions per heart. There was an excellent correlation (r =0.93, P<0.0001) between the Tc-MIBI uptake detected in the single and dual isotope acquisition. The average difference between the dual and single isotope Tc-MIBI uptake was -1.2% (not significantly different from zero) and the coefficient of variation of the difference was 8.7%. Of the 79 regions with irreversible perfusion defects on previous rest-stress Tc-MIBI, six regions in five patients showed a perfusion-metabolism mismatch pattern. We conclude that DISA does not affect the quality of the Tc-MIBI images. Furthermore, F-FDG- Tc-MIBI DISA may show viability in a small but significant (7.6%, P<0.0034) number of regions with irreversible perfusion defects on rest-stress Tc-MIBI.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12612465     DOI: 10.1097/00006231-200303000-00004

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  6 in total

1.  Dual isotope simultaneous imaging to evaluate the effects of intracoronary bone marrow-derived mesenchymal stem cells on perfusion and metabolism in canines with acute myocardial infarction.

Authors:  Linjun Hao; Jin Hao; Wei Fang; Chunlei Han; Kaixiu Zhang; Xuemei Wang
Journal:  Biomed Rep       Date:  2015-05-27

Review 2.  Application of animal and human PET in cardiac research.

Authors:  Quan Wang; Zhi-Gang He; Shun-Yuan Li; Mao-Hui Feng; Hong-Bing Xiang
Journal:  Am J Cardiovasc Dis       Date:  2018-06-15

3.  Functional and metabolic improvement after coronary intervention for non-viable myocardium detected by 18F fluorodeoxyglucose positron emission tomography.

Authors:  Kenji Fukushima; Hiroyuki Arashi; Yuichiro Minami; Risako Nakao; Michinobu Nagao; Koichiro Abe
Journal:  J Cardiol Cases       Date:  2019-05-03

4.  Comparison of 99mTc-sestamibi/18FDG DISA SPECT with PET for the detection of viability in patients with coronary artery disease and left ventricular dysfunction.

Authors:  Riemer H J A Slart; Jeroen J Bax; Jaep de Boer; Antoon T M Willemsen; Piet H Mook; Matthijs Oudkerk; Ernst E van der Wall; Dirk J van Veldhuisen; Pieter L Jager
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-04-12       Impact factor: 9.236

5.  Cell-permeable [99mTc(CO3)]-labeled fluorogenic caspase 3 substrate for dual-modality detection of apoptosis.

Authors:  Chiyi Xiong; Wei Lu; Rui Zhang; Mei Tian; William Tong; Juri Gelovani; Chun Li
Journal:  Chemistry       Date:  2009-09-14       Impact factor: 5.236

6.  Prediction of functional recovery after revascularization in patients with chronic ischaemic left ventricular dysfunction: head-to-head comparison between 99mTc-sestamibi/18F-FDG DISA SPECT and 13N-ammonia/ 18F-FDG PET.

Authors:  Riemer H J A Slart; Jeroen J Bax; Dirk J van Veldhuisen; Ernst E van der Wall; Roy Irwan; Wim J Sluiter; Rudi A Dierckx; Jaep de Boer; Pieter L Jager
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-03-08       Impact factor: 9.236

  6 in total