Monte Carlo model of the Elekta SLiplus accelerator: validation of a new MLC component module in BEAM for a 6 MV beam.

J Van de Walle1, C Martens, N Reynaert, H Palmans, M Coghe, W De Neve, C De Wagter, H Thierens.   

Abstract

A new component module (CM), called MLCE, has been implemented in the BEAM program. The CM takes into account the particular 'tongue-and-groove' design of the Elekta multi-leaf collimator (MLC) and the air gap between the leaves. The model was validated by two series of measurements and simulations. The first benchmarking series focuses on the interleaf leakage and the intraleaf transmission. The measurement showed a total transmission through the MLC of 1.42% of the open field dose. Two Monte Carlo (MC) simulations were made, the first with the new CM MLCE (inclusive of air gap) and the second with the CM MLCQ (exclusive of air gap), which is available in the BEAM distribution. When the air gap between the leaves was determined by varying the parameters of the leaf geometry within tolerance limits on the technical drawing, the total measured transmission of 1.42% was well reproduced by the CM MLCE. In contrast, MC simulations with MLCQ showed that the transmission through the MLC calculated without the interleaf leakage is only 44% of the total transmitted radiation. The relevance of the detailed MLC modelling was demonstrated also by studying the 'adjacent' tongue-and-groove effect, where two adjacent (not opposing) leaves are complementary, opened or closed. The two complementary leaf settings were simulated both with the CM MLCE and MLCQ. A comparison with measurements was made. In regions covered by two or more leaves, the dose increased by 14% for two leaves and by 40% for more than two leaves when the interleaf leakage was included in the transmission. The tongue-and-groove effect was perfectly reproduced by the MLCE module.

Entities:  

Mesh:

Year:  2003        PMID: 12608613     DOI: 10.1088/0031-9155/48/3/307

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Monte Carlo Modeling of the Agility MLC for IMRT and VMAT Calculations.

Authors:  Shingo Ohira; Hideki Takegawa; Masayoshi Miyazaki; Masahiko Koizumi; Teruki Teshima
Journal:  In Vivo       Date:  2020 Sep-Oct       Impact factor: 2.155

Review 2.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

3.  Suggesting a new design for multileaf collimator leaves based on Monte Carlo simulation of two commercial systems.

Authors:  Sanaz Hariri; Majid Shahriari
Journal:  J Appl Clin Med Phys       Date:  2010-06-15       Impact factor: 2.102

4.  Development of a dose verification system for Vero4DRT using Monte Carlo method.

Authors:  Yoshitomo Ishihara; Akira Sawada; Mitsuhiro Nakamura; Yuki Miyabe; Hiroaki Tanabe; Shuji Kaneko; Kenji Takayama; Takashi Mizowaki; Masaki Kokubo; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

5.  Intensity modulated arc therapy implementation in a three phase adaptive (18)F-FDG-PET voxel intensity-based planning strategy for head-and-neck cancer.

Authors:  Dieter Berwouts; Luiza Ana Maria Olteanu; Bruno Speleers; Frédéric Duprez; Indira Madani; Tom Vercauteren; Wilfried De Neve; Werner De Gersem
Journal:  Radiat Oncol       Date:  2016-04-02       Impact factor: 3.481

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.