Optimal marker placement in photogrammetry patient positioning system.

Haisong Liu1, Yan Yu, M C Schell, Walter G O'Dell, Russell Ruo, Paul Okunieff.   

Abstract

A photogrammetry-based patient positioning system has been used instead of the conventional laser alignment technique for patient set-up in external beam radiotherapy. It tracks skin affixed reflective markers with multiple infrared cameras. The three-dimensional (3D) positions of the markers provide reference information to determine the treatment plan isocenter location and hence provide the ability to position the lesion at the isocenter of the treatment linear accelerator. However, in current clinical practice for lung or liver lesion treatments, fiducial markers are usually randomly affixed onto the patients' chest and abdomen, so that the actual target registration error (TRE) of the internal lesions inside the body may be large, depending on the fiducial registration error (FRE). There exists an optimal marker configuration that can minimize the TRE. In this paper, we developed methods to design the patient-specific optimal configurations of the surface makers to minimize the TRE, given the patient's surface contour, the lesion position and the FRE. Floating genetic algorithm (GA) optimization was used to optimize the positions of the skin markers. The surface curve of the patient body was determined by an automatic segmentation algorithm from the planning CT. The method was evaluated using a body phantom implanted with a metal ball (a simulated target). By registering two CT scans using the surface markers and measuring the displacement of the target, the TRE was measured. The TRE was also measured by taking two orthogonal portal films after positioning the phantom using the photogrammetry based patient positioning system. A 50% reduction in TRE has been achieved by using the optimal configuration compared to the random configuration. This result demonstrates that the optimization of a fiducial configuration can result in improved tumor targeting ability.

Entities:  

Mesh:

Year:  2003        PMID: 12607826     DOI: 10.1118/1.1533748

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Effects of point configuration on the accuracy in 3D reconstruction from biplane images.

Authors:  Jacek Dmochowski; Kenneth R Hoffmann; Vikas Singh; Jinhui Xu; Daryl P Nazareth
Journal:  Med Phys       Date:  2005-09       Impact factor: 4.071

2.  Interventional navigation for abdominal therapy based on simultaneous use of MRI and ultrasound.

Authors:  J Hong; H Nakashima; K Konishi; S Ieiri; K Tanoue; M Nakamuta; M Hashizume
Journal:  Med Biol Eng Comput       Date:  2006-11-11       Impact factor: 2.602

3.  Real-time magnetic resonance imaging driven by electromagnetic locator for interventional procedure and endoscopic therapy.

Authors:  Jaesung Hong; Nobuhiko Hata; Kozo Konishi; Makoto Hashizume
Journal:  Surg Endosc       Date:  2007-11-01       Impact factor: 4.584

4.  An effective point-based registration tool for surgical navigation.

Authors:  Jaesung Hong; Makoto Hashizume
Journal:  Surg Endosc       Date:  2009-06-16       Impact factor: 4.584

5.  Optimization Model for the Distribution of Fiducial Markers in Liver Intervention.

Authors:  Qinyong Lin; Rongqian Yang; Lin Yang; Huazhou Chen; Bohan Li; Ken Cai
Journal:  J Med Syst       Date:  2020-03-09       Impact factor: 4.460

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.