Literature DB >> 12607622

A cross sectional study of water quality from dental unit water lines in dental practices in the West of Scotland.

A J Smith1, S McHugh, L McCormick, R Stansfield, A McMillan, J Hood.   

Abstract

OBJECTIVE: To determine the microbiological quality of water from dental units in a general practice setting and current practice for disinfection of units.
DESIGN: A cross-sectional study of the water quality from 40 dental units in 39 general practices and a questionnaire of the disinfection protocols used in those practices.
SETTING: NHS practices in primarydental care.
SUBJECTS: Thirty-nine general practices from the West of Scotland.
METHODS: Water samples were collected on two separate occasions from dental units and analysed for microbiological quality by the total viable count (TVC) method. Water specimens were collected from the triple syringe, high speed outlet, cup filler and surgery tap. Each participating practitioner was asked to complete a questionnaire. Results Microbial contamination was highest from the high speed outlet followed by the triple syringe and cup filler. On average, the TVC counts from the high speed water lines at 37 degrees C and for the high speed lines, triple syringe and cup filler at 22 degrees C were significantly higher than that from the control tap water specimens. The study included units from 11 different manufacturers with ages ranging from under one year to over eight years. The age of the dental unit analysed did not appear to influence the level of microbial contamination. Five of the practices surveyed used disinfectants to clean the dental units but these had no significant effect on the microbiological quality of the water. The majority of dental units (25 out of 40) were never flushed with water between patients. A number of different non-sterile irrigants were used for surgical procedures.
CONCLUSION: The microbiological quality of water from dental units in general dental practice is poor compared with that from drinking water sources. Suitable sterile irrigants should be used for surgical procedures in dental practice. Further work is required for pragmatic decontamination regimens of dental unit water lines in a general dental practice setting

Entities:  

Mesh:

Year:  2002        PMID: 12607622     DOI: 10.1038/sj.bdj.4801651

Source DB:  PubMed          Journal:  Br Dent J        ISSN: 0007-0610            Impact factor:   1.626


  8 in total

1.  Appraisal of microbial contamination of dental unit water systems and practices of general dental practitioners for risk reduction.

Authors:  Bajrang Lal; Khaiwal Ravindra; Manisha Biswal
Journal:  Environ Sci Pollut Res Int       Date:  2018-09-29       Impact factor: 4.223

2.  Assessment of inhibitory effects of fluoride-coated tubes on biofilm formation by using the in vitro dental unit waterline biofilm model.

Authors:  Toshiaki Yabune; Satoshi Imazato; Shigeyuki Ebisu
Journal:  Appl Environ Microbiol       Date:  2008-08-01       Impact factor: 4.792

3.  Comparison of the efficacies of disinfectants to control microbial contamination in dental unit water systems in general dental practices across the European Union.

Authors:  A J Schel; P D Marsh; D J Bradshaw; M Finney; M R Fulford; E Frandsen; E Østergaard; J M ten Cate; W R Moorer; A Mavridou; J J Kamma; G Mandilara; L Stösser; S Kneist; R Araujo; N Contreras; P Goroncy-Bermes; D O'Mullane; F Burke; P O'Reilly; G Hourigan; M O'Sullivan; R Holman; J T Walker
Journal:  Appl Environ Microbiol       Date:  2006-02       Impact factor: 4.792

4.  Occurrence and biofilm forming ability of Pseudomonas aeruginosa in the water output of dental unit waterlines in a dental center in Alexandria, Egypt.

Authors:  Sheref Gawish; Aleya Abbass; Amani Abaza
Journal:  Germs       Date:  2019-06-03

5.  Evaluation of gram negative bacterial contamination in dental unit water supplies in a university clinic in tabriz, iran.

Authors:  Firoz Pouralibaba; Esrafil Balaei; Atabak Kashefimehr
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2011-09-05

6.  A pilot study of bioaerosol reduction using an air cleaning system during dental procedures.

Authors:  C Hallier; D W Williams; A J C Potts; M A O Lewis
Journal:  Br Dent J       Date:  2010-10-15       Impact factor: 1.626

7.  Dental Unit Waterlines: A Survey of Practices in Eastern France.

Authors:  Alexandre Baudet; Julie Lizon; Jean-Marc Martrette; Frédéric Camelot; Arnaud Florentin; Céline Clément
Journal:  Int J Environ Res Public Health       Date:  2019-11-01       Impact factor: 3.390

8.  Efficacy of BRS® and Alpron®/Bilpron® Disinfectants for Dental Unit Waterlines: A Six-Year Study.

Authors:  Alexandre Baudet; Julie Lizon; Jean-Marc Martrette; Frédéric Camelot; Arnaud Florentin; Céline Clément
Journal:  Int J Environ Res Public Health       Date:  2020-04-12       Impact factor: 3.390

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.