Literature DB >> 12601829

Three-dimensional ultrasound fetal lung volume measurement: a systematic study comparing the multiplanar method with the rotational (VOCAL) technique.

K D Kalache1, J Espinoza, T Chaiworapongsa, J Londono, M L Schoen, M C Treadwell, W Lee, R Romero.   

Abstract

OBJECTIVES: This study was designed to compare a conventional multiplanar technique for three-dimensional (3D) ultrasound measurement of fetal lung volume with a rotational method using VOCAL trade mark (Virtual Organ Computer-aided AnaLysis).
METHODS: Thirty-two fetuses with a variety of conditions at risk for pulmonary hypoplasia were studied. 3D volume data sets of the fetal lungs were acquired using a commercially available ultrasound system. The right and left lung volumes were calculated separately using VOCAL and the multiplanar technique. The level of agreement between two independent observers in categorizing the 3D volume data set as measurable or non-measurable was determined. The interobserver and intermethod variabilities were also evaluated for both methods.
RESULTS: The intermethod variability was excellent (correlation r = 0.93 and r = 0.96 for the left and right lung, respectively), and there was substantial agreement between the results of both approaches (limits of agreement - 4.4 to 8.9 and - 3.4 to 4.8 mL for the right and left lung, respectively). Fetal lung estimation with VOCAL had a significantly higher interobserver variability than the multiplanar technique. Interobserver agreement in categorizing lung volume data sets as measurable or non-measurable was lower when VOCAL was used.
CONCLUSION: Fetal lung volume measurements can be undertaken interchangeably using the multiplanar technique or the rotational method with VOCAL. However, the latter was less reproducible (lower degree of agreement and significantly higher interobserver variability) than the former. Copyright 2003 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2003        PMID: 12601829     DOI: 10.1002/uog.39

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  8 in total

Review 1.  Three- and 4-dimensional ultrasound in obstetric practice: does it help?

Authors:  Luís F Gonçalves; Wesley Lee; Jimmy Espinoza; Roberto Romero
Journal:  J Ultrasound Med       Date:  2005-12       Impact factor: 2.153

2.  Quantitative assessment of gestational sac shape: the gestational sac shape score.

Authors:  R L Deter; J Li; W Lee; S Liu; R Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2007-05       Impact factor: 7.299

3.  The use of inversion mode and 3D manual segmentation in volume measurement of fetal fluid-filled structures: comparison with Virtual Organ Computer-aided AnaLysis (VOCAL).

Authors:  J P Kusanovic; J K Nien; L F Gonçalves; J Espinoza; W Lee; M Balasubramaniam; E Soto; O Erez; R Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2008-02       Impact factor: 7.299

4.  Three-dimensional sonographic volume measurement of the fetal cerebellum.

Authors:  Toshiyuki Hata; Atsushi Kuno; Shu-Yan Dai; Eisuke Inubashiri; Uiko Hanaoka; Kenji Kanenishi; Chizu Yamashiro; Hirokazu Tanaka; Toshihiro Yanagihara
Journal:  J Med Ultrason (2001)       Date:  2007-03-15       Impact factor: 1.314

5.  Volumetric growth of the lungs in human fetuses: an anatomical, hydrostatic and statistical study.

Authors:  Michał Szpinda; Waldemar Siedlaczek; Anna Szpinda; Alina Woźniak; Celestyna Mila-Kierzenkowska; Marcin Wiśniewski
Journal:  Surg Radiol Anat       Date:  2014-02-18       Impact factor: 1.246

6.  Estimation of uterine volume: A comparison between Viewpoint and 3D ultrasound estimation in women undergoing laparoscopic hysterectomy.

Authors:  Ishwari Casikar; Max Mongelli; Shannon Reid; George Condous
Journal:  Australas J Ultrasound Med       Date:  2015-12-31

7.  Magnetic resonance imaging of the fetal lung: a pictorial essay.

Authors:  M Cannie; J Jani; F De Keyzer; F Van Kerkhove; J Meersschaert; L Lewi; J Deprest; S Dymarkowski
Journal:  Eur Radiol       Date:  2008-02-13       Impact factor: 7.034

8.  Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method.

Authors:  Sung-Hye You; Sang-Il Suh; In-Seon Ryoo; Gyu-Ri Son; Young-Hen Lee; Hyung Suk Seo; Nam Joon Lee; Hae Young Seol
Journal:  Ultrasonography       Date:  2016-06-08
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.