Literature DB >> 12598993

Effect of subcutaneous butylscopolamine administration in the reduction of peristaltic artifacts in 1.5-T MR fast abdominal examinations.

Rosa Dosdá1, Luis Martí-Bonmatí, Crisanto L Ronchera-Oms, Enrique Mollá, Estanislao Arana.   

Abstract

In abdominal MR imaging, ghost artifacts from noncyclic bowel movements can reduce the quality of the images. Although pharmacologic suppression of motion is effective, no study has being conducted to analyze the influence of drug motion suppression on fast breath-hold 1.5-T examinations of the upper abdomen. A prospective, randomized, double-blind trial was conducted in 50 patients. Patients were randomly distributed into two groups: The control group received only an oral solution, whereas the other group received the oral solution plus a subcutaneous injection of 20 mg of butylscopolamine 10 min before the MR examination. Breath-hold T1-weighted gradient-recalled-echo (GRE) MR images were obtained in a 1.5-T superconductive unit. Quantitative image analysis was performed with region-of-interest (ROI) measurements of the signal intensity of the liver and in background air anterior and lateral to the patient. A qualitative analysis of the subjective quality of the T1-weighted images was also done, and the adverse reactions were registered. The groups were homogeneous regarding age, gender, and weight distribution. No significant differences in the signal intensity of the liver and in the incoherent noise measurements were found between the two groups. Gastrointestinal noise showed significant differences between groups, with lower values for the butylscopolamine group compared with the control group. There was also a statistically significant difference in the image quality between groups, and optimal studies were only found in the butylscopolamine group, where most patients had a good-quality evaluation. Regarding adverse events, there were non-significant differences between groups. In conclusion, administration of an antiperistaltic agent to reduce the movements of the gastrointestinal tract diminishes the motion artifacts generated on MR imaging of the abdomen, even at high field strength and with fast imaging sequences. Images of the upper abdomen obtained after pharmacologic suppression of the gastrointestinal movement are of significantly superior quality.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12598993     DOI: 10.1007/s00330-002-1500-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  9 in total

1.  Whole-body MRI of paediatric malignant tumours: comparison with conventional oncological imaging methods.

Authors:  Hyun Woo Goo; Seong Hoon Choi; Thad Ghim; Hyung Nam Moon; Jong Jin Seo
Journal:  Pediatr Radiol       Date:  2005-04-28

2.  Prostate magnetic resonance imaging at 3 Tesla: Is administration of hyoscine-N-butyl-bromide mandatory?

Authors:  Matthias C Roethke; Timur H Kuru; Alexander Radbruch; Boris Hadaschik; Heinz-Peter Schlemmer
Journal:  World J Radiol       Date:  2013-07-28

3.  Hyoscine butylbromide significantly decreases motion artefacts and allows better delineation of anatomic structures in mp-MRI of the prostate.

Authors:  T Ullrich; M Quentin; A K Schmaltz; C Arsov; C Rubbert; D Blondin; R Rabenalt; P Albers; G Antoch; L Schimmöller
Journal:  Eur Radiol       Date:  2017-07-07       Impact factor: 5.315

4.  In vitro effects of PDE5 inhibitors sildenafil, vardenafil and tadalafil on isolated human ureteral smooth muscle: a basic research approach.

Authors:  Christian Gratzke; Stefan Uckert; Giorgi Kedia; Oliver Reich; Boris Schlenker; Michael Seitz; Armin J Becker; Christian G Stief
Journal:  Urol Res       Date:  2006-11-11

5.  Aperistaltic effect of hyoscine N-butylbromide versus glucagon on the small bowel assessed by magnetic resonance imaging.

Authors:  Johannes M Froehlich; Muriel Daenzer; Constantin von Weymarn; S Mehmet Erturk; Christoph L Zollikofer; Michael A Patak
Journal:  Eur Radiol       Date:  2009-02-04       Impact factor: 5.315

6.  Value of bowel preparation techniques for prostate MRI: a preliminary study.

Authors:  Cynthia Schmidt; Andreas M Hötker; Urs J Muehlematter; Irene A Burger; Olivio F Donati; Borna K Barth
Journal:  Abdom Radiol (NY)       Date:  2021-03-26

7.  Pseudo-random Trajectory Scanning Suppresses Motion Artifacts on Gadoxetic Acid-enhanced Hepatobiliary-phase Magnetic Resonance Images.

Authors:  Yuko Nakamura; Toru Higaki; Takashi Nishihara; Kuniaki Harada; Masahiro Takizawa; Yoshitaka Bito; Keigo Narita; Motonori Akagi; Yoshiko Matsubara; Shogo Kamioka; Yuji Akiyama; Makoto Iida; Kazuo Awai
Journal:  Magn Reson Med Sci       Date:  2019-03-18       Impact factor: 2.471

8.  A feasibility study of hyoscine butylbromide (buscopan) to improve image quality of cone beam computed tomography during abdominal/pelvic Stereotactic Ablative Radiotherapy.

Authors:  Finbar Slevin; Matthew Beasley; Jim Zhong; Eleanor Hudson; Richard Speight; John Lilley; Louise J Murray; Ann M Henry
Journal:  BJR Open       Date:  2021-07-29

9.  Efficacy of butylscopolamine in obtaining clear MR image for intensity-modulated radiotherapy for prostate cancer.

Authors:  Osamu Tanaka; Hisao Komeda; Masayoshi Tamaki; Kensaku Seike; Shota Fujimoto; Eiichi Yama; Shigeki Hirose; Masayuki Matsuo
Journal:  Tech Innov Patient Support Radiat Oncol       Date:  2017-09-01