Apparatus for measuring the swelling dependent electrical conductivity of charged hydrated soft tissues.

W Y Gu1, M A Justiz.   

Abstract

This paper describes a new apparatus and method for measuring swelling dependent electrical conductivity of charged hydrated soft tissues. The apparatus was calibrated using a conductivity standard. Swelling dependent specific conductivity of porcine annulus fibrosis (AF) samples was determined. The conductivity values for porcine AF were similar to those for human and bovine articular cartilage found in the literature. Results revealed a significant linear correlation between specific conductivity and water content for porcine AF tissues tested in phosphate buffered saline (PBS).

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12596649     DOI: 10.1115/1.1516571

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  8 in total

1.  Anisotropic diffusive transport in annulus fibrosus: experimental determination of the diffusion tensor by FRAP technique.

Authors:  Francesco Travascio; Wei Yong Gu
Journal:  Ann Biomed Eng       Date:  2007-06-29       Impact factor: 3.934

2.  Effect of compression and anisotropy on the diffusion of glucose in annulus fibrosus.

Authors:  Alicia R Jackson; Tai-Yi Yuan; Chun-Yuh C Huang; Francesco Travascio; Wei Yong Gu
Journal:  Spine (Phila Pa 1976)       Date:  2008-01-01       Impact factor: 3.468

3.  Novel technique for online characterization of cartilaginous tissue properties.

Authors:  Tai-Yi Yuan; Chun-Yuh Huang; Wei Yong Gu
Journal:  J Biomech Eng       Date:  2011-09       Impact factor: 2.097

4.  Effect of mechanical loading on electrical conductivity in human intervertebral disk.

Authors:  Alicia R Jackson; Francesco Travascio; Wei Yong Gu
Journal:  J Biomech Eng       Date:  2009-05       Impact factor: 2.097

5.  Effect of mechanical strain on solute diffusion in human TMJ discs: an electrical conductivity study.

Authors:  Gregory J Wright; Jonathan Kuo; Changcheng Shi; Thierry R H Bacro; Elizabeth H Slate; Hai Yao
Journal:  Ann Biomed Eng       Date:  2013-06-15       Impact factor: 3.934

6.  A conductivity approach to measuring fixed charge density in intervertebral disc tissue.

Authors:  Alicia R Jackson; Tai-Yi Yuan; Chun-Yuh Huang; Wei Yong Gu
Journal:  Ann Biomed Eng       Date:  2009-09-11       Impact factor: 3.934

7.  Strain-dependent oxygen diffusivity in bovine annulus fibrosus.

Authors:  T-Y Yuan; A R Jackson; C-Y Huang; W Y Gu
Journal:  J Biomech Eng       Date:  2009-07       Impact factor: 2.097

8.  Relationship between solute transport properties and tissue morphology in human annulus fibrosus.

Authors:  Francesco Travascio; Alicia R Jackson; Mark D Brown; Wei Yong Gu
Journal:  J Orthop Res       Date:  2009-12       Impact factor: 3.494

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.