Literature DB >> 12594986

Modeling of time-dependent force response of fingertip to dynamic loading.

J Z Wu1, R G Dong, W P Smutz, A W Schopper.   

Abstract

An extended exposure to repeated loading on fingertip has been associated to many vascular, sensorineural, and musculoskeletal disorders in the fingers, such as carpal tunnel syndrome, hand-arm vibration syndrome, and flexor tenosynovitis. A better understanding of the pathomechanics of these sensorineural and vascular diseases in fingers requires a formulation of a biomechanical model of the fingertips and analyses to predict the mechanical responses of the soft tissues to dynamic loading. In the present study, a model based on finite element techniques has been developed to simulate the mechanical responses of the fingertips to dynamic loading. The proposed model is two-dimensional and incorporates the essential anatomical structures of a finger: skin, subcutaneous tissue, bone, and nail. The skin tissue is assumed to be hyperelastic and viscoelastic. The subcutaneous tissue was considered to be a nonlinear, biphasic material composed of a hyperelastic solid and an invicid fluid, while its hydraulic permeability was considered to be deformation dependent. Two series of numerical tests were performed using the proposed finger tip model to: (a) simulate the responses of the fingertip to repeated loading, where the contact plate was assumed to be fixed, and the bone within the fingertip was subjected to a prescribed sinusoidal displacement in vertical direction; (b) simulate the force response of the fingertip in a single keystroke, where the keyboard was composed of a hard plastic keycap, a rigid support block, and a nonlinear spring. The time-dependent behavior of the fingertip under dynamic loading was derived. The model predictions of the time-histories of force response of the fingertip and the phenomenon of fingertip separation from the contacting plate during cyclic loading agree well with the reported experimental observations.

Entities:  

Mesh:

Year:  2003        PMID: 12594986     DOI: 10.1016/s0021-9290(02)00427-x

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

1.  Flexor tendon and synovial gliding during simultaneous and single digit flexion in idiopathic carpal tunnel syndrome.

Authors:  Anke M Ettema; Kai-Nan An; Chunfeng Zhao; Megan M O'Byrne; Peter C Amadio
Journal:  J Biomech       Date:  2007-10-22       Impact factor: 2.712

2.  Threshold position control of arm movement with anticipatory increase in grip force.

Authors:  Jean-François Pilon; Sophie J De Serres; Anatol G Feldman
Journal:  Exp Brain Res       Date:  2007-03-06       Impact factor: 2.064

Review 3.  Age-dependent biomechanical properties of the skin.

Authors:  Mariola Pawlaczyk; Monika Lelonkiewicz; Michał Wieczorowski
Journal:  Postepy Dermatol Alergol       Date:  2013-10-30       Impact factor: 1.837

Review 4.  Rubbing-Assisted Approach for Fabricating Oriented Nanobiomaterials.

Authors:  Yadong Chai; Yanni Zhou; Motohiro Tagaya
Journal:  Micromachines (Basel)       Date:  2022-08-20       Impact factor: 3.523

5.  Fluid-structure interaction-based biomechanical perception model for tactile sensing.

Authors:  Zheng Wang
Journal:  PLoS One       Date:  2013-11-19       Impact factor: 3.240

6.  The Finite Element Simulation of the Upper Airway of Patients with Moderate and Severe Obstructive Sleep Apnea Hypopnea Syndrome.

Authors:  Huiping Luo; Austin Scholp; Jack J Jiang
Journal:  Biomed Res Int       Date:  2017-10-24       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.