Literature DB >> 12592552

Posterior atlanto-axial fusion with the Olerud Cervical Fixation System for odontoid fractures and C1-C2 instability in rheumatoid arthritis.

M Cornefjord1, T Henriques, M Alemany, C Olerud.   

Abstract

In posterior C1-C2 fusion, traditional wire fixation gives poor stability. The bone quality is often insufficient to provide the competent structural bone graft that is required, and the introduction of sublaminar wires is somewhat dangerous. The stability is markedly improved by adding transarticular screws, but the drawbacks of structural bone graft and sublaminar wires remain. The C1 claw of the Olerud Cervical Fixation System improves C1-C2 fixation without relying on structural bone graft or compromising the spinal canal. The aim of this study was to evaluate radiological healing and possible complications in a consecutive series of C1-C2 fusions from our department operated with the C1 claw device. Twenty-six patients (14 women) with a mean age of 73 (range 37-93) years were included. The diagnoses were odontoid fracture in 18 patients, rheumatoid instability in 6, and odontoid non-union and os odontoideum in 1 each. The patients were followed clinically and with plain radiographs for an average of 15 (range 3-27) months. There were no neurological or vascular complications, and no secondary displacements or reoperations in the series. Twenty patients followed for 6-27 months were radiographically healed. Six patients died from unrelated causes 1-38 months postoperatively. Three of these patients had no radiographs later than the postoperative control, one had a healed odontoid fracture but resorbed bone graft at 8 months, while the remaining two patients were not healed, but showed no signs of healing disturbance at the time of death. On the basis of the findings of this study, posterior C1-C2 fusion with the Olerud Cervical Fixation System seems promising. No serious complications related to the surgical procedure were encountered. The stability of the implant obviates the use of a solid bone block as a graft and still allows a high frequency of fusion healing.

Entities:  

Mesh:

Year:  2002        PMID: 12592552     DOI: 10.1007/s00586-002-0470-2

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  9 in total

Review 1.  [Instability of the upper cervical spine due to rheumatism].

Authors:  C E Heyde; U Weber; R Kayser
Journal:  Orthopade       Date:  2006-03       Impact factor: 1.087

2.  Potential intraoperative factors of screw-related complications following posterior transarticular C1-C2 fixation: a systematic review and meta-analysis.

Authors:  Ivan Lvov; Andrey Grin; Aleksandr Talypov; Anton Kordonskiy; Vladimir Smirnov; Iliya Grigoriev; Ulugbek Khushnazarov; Vladimir Krylov
Journal:  Eur Spine J       Date:  2018-11-22       Impact factor: 3.134

3.  C1-2 transarticular screws combined with C1 laminar hooks fixation: a modified posterior atlantoaxial fixation technique and outcome in 72 patients.

Authors:  Bin Ni; Xiang Guo; Ning Xie; Songkai Li; Fengjing Zhou; Feng Zhang; Qi Liu
Journal:  Eur Spine J       Date:  2012-08-21       Impact factor: 3.134

4.  CT analysis of the axis for transarticular screw fixation of rheumatoid atlantoaxial instability.

Authors:  Sung Soo Chung; Chong Suh Lee; Hye Won Chung; Chang Seok Kang
Journal:  Skeletal Radiol       Date:  2006-06-27       Impact factor: 2.199

Review 5.  [Therapy of cervical rheumatoid arthritis].

Authors:  R Kothe; L Wiesner; W Rüther
Journal:  Z Rheumatol       Date:  2004-08       Impact factor: 1.372

6.  Erosion in the occipital bone caused by the fixation instrument used for posterior atlantoaxial fusion -report of 4 cases.

Authors:  Fumihiro Arizumi; Tokuhide Moriyama; Toshiya Tachibana; Keishi Maruo; Shinichi Inoue; Takanobu Manabe; Shinichi Yoshiya
Journal:  Springerplus       Date:  2015-03-21

Review 7.  Systematic review on surgical and nonsurgical treatment of type II odontoid fractures in the elderly.

Authors:  Yohan Robinson; Anna-Lena Robinson; Claes Olerud
Journal:  Biomed Res Int       Date:  2014-02-10       Impact factor: 3.411

8.  Biomechanical Assessment of Stabilization of Simulated Type II Odontoid Fracture with Case Study.

Authors:  Roy T Daniel; Mir M Hussain; Noelle Klocke; Soumya S Yandamuri; Lukas Bobinski; John M Duff; Brandon S Bucklen
Journal:  Asian Spine J       Date:  2017-02-17

9.  Bilateral C1-C2 transarticular screw and C1 laminar hook fixation and bone graft fusion for reducible atlantoaxial dislocation: a seven-year analysis of outcome.

Authors:  Xiang Guo; Bin Ni; Ning Xie; Xuhua Lu; Qunfeng Guo; Ming Lu
Journal:  PLoS One       Date:  2014-01-31       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.