Interaction of intraocular lenses with various concentrations of silicone oil: an experimental study.

F Hakan Oner1, Osman A Saatci, Sülen Sarioğlu, Ismet Durak, Süleyman Kaynak, Metin Cabuk.   

Abstract

The aim of this study was to evaluate the interaction between various widely used intraocular lenses (IOLs) and silicone oils of different viscosities. Four groups of IOLs, including monoblock foldable hydrophilic acrylic IOLs (Morcher, type 92s); monoblock hydrophobic acrylic IOLs (Acrysof-SA60AT, Alcon); single-piece rigid polymethylmethacrylate (PMMA) IOLs (Intraocular Optical International-IOI-65130) and a three-piece foldable silicone optic IOL (CeeOn Edge 911A, Pharmacia UpJohn) were analyzed in vitro to determine the percentage adherence 1,000-centistoke, 1,300-centistoke or 5,000-centistokes silicone oil on the IOL optic. For each IOL type, there was no statistically significant difference in the mean silicone oil coverage (MSC) of the IOL optics for the different viscosities of silicone oil. Silicone IOLs had the highest MSC percentage (79.9%) whereas hydrophilic acrylic IOLs were the least silicone-covered IOLs (7.8%) compared to the other IOL types tested in this study. It is not the concentration of silicone oil that affects silicone oil coverage. When performing small-incision cataract surgery in patients who may require silicone oil injection, foldable hydrophilic acrylic or hydrophobic acrylic lenses should be preferred over standard foldable silicone lenses. Copyright 2003 S. Karger AG, Basel

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12592051     DOI: 10.1159/000068561

Source DB:  PubMed          Journal:  Ophthalmologica        ISSN: 0030-3755            Impact factor:   3.250


  3 in total

1.  Outcome of phacoemulsification in patients with uveitis.

Authors:  M A Elgohary; P J McCluskey; H M A Towler; N Okhravi; R P Singh; R Obikpo; S S Lightman
Journal:  Br J Ophthalmol       Date:  2007-01-17       Impact factor: 4.638

2.  Prediction of refractive error in combined vitrectomy and cataract surgery with one-piece acrylic intraocular lens.

Authors:  Dong Kyu Lee; Sung Jin Lee; Yong Sung You
Journal:  Korean J Ophthalmol       Date:  2008-12

3.  Intraocular lens dystrophic calcification after trans-scleral diode laser treatment for a cyclodialysis cleft.

Authors:  Anmar Abdul-Rahman; Philip House; Josephine Richards
Journal:  Am J Ophthalmol Case Rep       Date:  2018-06-20