Literature DB >> 12591631

Increase in vertebral body height after vertebroplasty.

Akio Hiwatashi1, Toshio Moritani, Yuji Numaguchi, Per-Lennart Westesson.   

Abstract

BACKGROUND AND
PURPOSE: During clinical work, we have seen increases in vertebral body height associated with vertebroplasty, but our literature search revealed no reports as to how often and to what degree those increases occur. The purpose of this study was to document the frequency and degree of changes in vertebral body height after vertebroplasty.
METHODS: The heights of 85 vertebral bodies in 37 patients were measured before and after vertebroplasty. In addition, one adjacent vertebral body was measured in each patient as a control. Twenty-six patients had compression fractures in the thoracic spine, and 24 patients had compression fractures in the lumbar spine. Vertebroplasty was performed with a bilateral transpedicular approach by injecting polymethylmethacrylate, under biplane fluoroscopic control. Measurements were performed on preoperative MR images and on postoperative CT sagittal reformations. Anterior, central, and posterior vertebral body height measurements were obtained in the midsagittal plane.
RESULTS: The average increase in vertebral body height was 2.5 mm anteriorly, 2.7 mm centrally, and 1.4 mm posteriorly. Thirteen of 85 treated vertebrae remained unchanged. All control vertebral bodies also remained unchanged.
CONCLUSION: Vertebral body height often increases during vertebroplasty. The clinical significance of increasing vertebral body height is unknown.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12591631      PMCID: PMC7974119     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  14 in total

Review 1.  Percutaneous vertebroplasty: a developing standard of care for vertebral compression fractures.

Authors:  J M Mathis; J D Barr; S M Belkoff; M S Barr; M E Jensen; H Deramond
Journal:  AJNR Am J Neuroradiol       Date:  2001-02       Impact factor: 3.825

2.  An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty.

Authors:  S M Belkoff; J M Mathis; H Deramond; L E Jasper
Journal:  AJNR Am J Neuroradiol       Date:  2001 Jun-Jul       Impact factor: 3.825

3.  Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures.

Authors:  I H Lieberman; S Dudeney; M K Reinhardt; G Bell
Journal:  Spine (Phila Pa 1976)       Date:  2001-07-15       Impact factor: 3.468

4.  Acute osteoporotic vertebral collapse: open study on percutaneous injection of acrylic surgical cement in 20 patients.

Authors:  C Cyteval; M P Sarrabère; J O Roux; E Thomas; C Jorgensen; F Blotman; J Sany; P Taourel
Journal:  AJR Am J Roentgenol       Date:  1999-12       Impact factor: 3.959

5.  Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects.

Authors:  M E Jensen; A J Evans; J M Mathis; D F Kallmes; H J Cloft; J E Dion
Journal:  AJNR Am J Neuroradiol       Date:  1997 Nov-Dec       Impact factor: 3.825

6.  Percutaneous vertebroplasty in patients with osteolytic metastases or multiple myeloma.

Authors:  B Cortet; A Cotten; N Boutry; F Dewatre; R M Flipo; B Duquesnoy; P Chastanet; B Delcambre
Journal:  Rev Rhum Engl Ed       Date:  1997-03

Review 7.  Percutaneous vertebroplasty: state of the art.

Authors:  A Cotten; N Boutry; B Cortet; R Assaker; X Demondion; D Leblond; P Chastanet; B Duquesnoy; H Deramond
Journal:  Radiographics       Date:  1998 Mar-Apr       Impact factor: 5.333

8.  Percutaneous vertebroplasty for pain relief and spinal stabilization.

Authors:  J D Barr; M S Barr; T J Lemley; R M McCann
Journal:  Spine (Phila Pa 1976)       Date:  2000-04-15       Impact factor: 3.468

9.  Percutaneous vertebroplasty for osteolytic metastases and myeloma: effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up.

Authors:  A Cotten; F Dewatre; B Cortet; R Assaker; D Leblond; B Duquesnoy; P Chastanet; J Clarisse
Journal:  Radiology       Date:  1996-08       Impact factor: 11.105

10.  [Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty].

Authors:  P Galibert; H Deramond; P Rosat; D Le Gars
Journal:  Neurochirurgie       Date:  1987       Impact factor: 1.553

View more
  37 in total

1.  Percutaneous balloon kyphoplasty with the patient under intravenous analgesia and sedation: a feasibility study.

Authors:  M Mohr; D Pillich; M Kirsch; J U Mueller; S Fleck; N Hosten; S Langner
Journal:  AJNR Am J Neuroradiol       Date:  2011-01-27       Impact factor: 3.825

2.  Percutaneous vertebroplasty: complication avoidance and technique optimization.

Authors:  John M Mathis
Journal:  AJNR Am J Neuroradiol       Date:  2003-09       Impact factor: 3.825

Review 3.  Vertebroplasty versus kyphoplasty: a comparison and contrast.

Authors:  John M Mathis; A Orlando Ortiz; Gregg H Zoarski
Journal:  AJNR Am J Neuroradiol       Date:  2004-05       Impact factor: 3.825

4.  Is there really no benefit of vertebroplasty for osteoporotic vertebral fractures? A meta-analysis.

Authors:  Ming-Min Shi; Xun-Zi Cai; Tiao Lin; Wei Wang; Shi-Gui Yan
Journal:  Clin Orthop Relat Res       Date:  2012-06-23       Impact factor: 4.176

5.  Taking vertebroplasty to a new level or making a mountain out of a molehill?

Authors:  Harry J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2005-03       Impact factor: 3.825

Review 6.  Vertebroplasty and kyphoplasty: rapid pain relief for vertebral compression fractures.

Authors:  Robert G Dixon; John M Mathis
Journal:  Curr Osteoporos Rep       Date:  2004-12       Impact factor: 5.096

7.  Percutaneous vertebroplasty or kyphoplasty: which one do I choose?

Authors:  John M Mathis
Journal:  Skeletal Radiol       Date:  2006-09       Impact factor: 2.199

Review 8.  Kyphoplasty and vertebroplasty: how good is the evidence?

Authors:  Fergus E McKiernan
Journal:  Curr Rheumatol Rep       Date:  2007-04       Impact factor: 4.592

Review 9.  Kyphoplasty: an assessment of a new technology.

Authors:  H J Cloft; M E Jensen
Journal:  AJNR Am J Neuroradiol       Date:  2007-02       Impact factor: 3.825

10.  Refractures in cemented vertebrae after percutaneous vertebroplasty: a retrospective analysis.

Authors:  Wei-Che Lin; Yu-Chang Lee; Chen-Hsiang Lee; Yeh-Lin Kuo; Yu-Fan Cheng; Chun-Chung Lui; Tien-Tsai Cheng
Journal:  Eur Spine J       Date:  2008-01-18       Impact factor: 3.134

View more