Literature DB >> 12589284

Dimensional change in complete dentures fabricated by injection molding and microwave processing.

Phillip L J Keenan1, David R Radford, Robert K F Clark.   

Abstract

STATEMENT OF PROBLEM: Acrylic resin complete dentures undergo dimensional changes during polymerization. Techniques with injection molding and polymerization and microwave polymerization are reported to reduce these changes and thereby improve clinical fit. These dimensional changes need to be quantified.
PURPOSE: The purpose of this study was to compare differences in dimensional changes of simulated maxillary complete dentures during polymerization and storage in water after injection molding and conventional polymerization, or microwave polymerization against a control of conventionally packed and polymerized simulated maxillary complete dentures.
MATERIAL AND METHODS: Forty identical maxillary denture bases were prepared in dental wax with anatomic teeth. They were invested and the wax eliminated from the molds. Ten specimens each were randomly assigned to 1 of 4 groups. Group 1 was compression molded and conventionally polymerized; group 2 was injection molded and conventionally polymerized (Success); group 3 was injection molded and microwave polymerized (Acron MC); and group 4 was injection molded and microwave polymerized (Microbase). Intermolar width and changes in vertical dimension of occlusion, were determined after polymerization and after storage in water for 28 days. Measurements in triplicate were made between points scribed on the second molar teeth with a traveling microscope (accurate to 0.005 mm). Vertical dimension of occlusion was measured between points scribed on the upper and lower members of an articulator by use of an internal micrometer (accurate to 0.05 mm). Data were analyzed by use of a 1-way analysis of variance with Tukey post-hoc contrasts (P <.05).
RESULTS: Polymerization contractions (intermolar widths) for each group were: group 1, -0.24%; group 2, -0.27%; group 3, -0.35%; and group 4, -0.37%. The Microbase specimens had greater shrinkage than conventionally polymerized specimens, but there were no significant differences between the groups. All injection methods had less postpolymerization increase in vertical dimension of occlusion (0.63 to 0.41 mm) than the conventional Trevalon control (0.74 mm), but only group 4 was significantly different (P<.004). After storage in water for 28 days, all specimens increased in vertical dimension of occlusion (0.10% to 0.16%) from polymerization techniques, but there were no significant differences between groups.
CONCLUSION: Within the limitations of this study, injection molding resulted in a slightly less increase of vertical dimension of occlusion than conventional polymerization techniques, the difference being significant for Microbase compared with the conventional Trevalon control.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12589284     DOI: 10.1067/mpr.2003.3

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  8 in total

1.  Teeth movement in denture and implant-supported prosthesis influenced by microwave flask systems.

Authors:  Rafael L X Consani; Leonardo G Sonehara; Marcelo F Mesquita; Valentim A R Barão; Conrado R Caetano
Journal:  J Oral Biol Craniofac Res       Date:  2015-07-15

2.  Influence of high expansion dental stone used as investing medium on the changes in occlusal vertical dimension of complete dentures.

Authors:  Alaa'a M Salloum
Journal:  Saudi Dent J       Date:  2013-10-28

3.  Flexible thermoplastic denture base materials for aesthetical removable partial denture framework.

Authors:  Kunwarjeet Singh; Himanshu Aeran; Narender Kumar; Nidhi Gupta
Journal:  J Clin Diagn Res       Date:  2013-10-05

4.  Comparison of cooling methods on denture base adaptation of rapid heat-cured acrylic using a three-dimensional superimposition technique.

Authors:  Lee Wei May; Jacob John; Lim Ghee Seong; Zubaidah Zanul Abidin; Norliza Ibrahim; Mahmoud Danaee; Noorhayati Raja Mohd
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

5.  Effect of the processing cycle on dimensional changes of heat-polymerized denture base resins.

Authors:  Ghazal Savabi; Omid Savabi; Badrosadat Dastgheib; Farahnaz Nejatidanesh
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug

6.  Dimensional changes of acrylic resin denture bases: conventional versus injection-molding technique.

Authors:  Jafar Gharechahi; Nafiseh Asadzadeh; Foad Shahabian; Maryam Gharechahi
Journal:  J Dent (Tehran)       Date:  2014-07-31

7.  Effect of biofilm formation, and biocorrosion on denture base fractures.

Authors:  Cem Sahin; Alper Ergin; Simel Ayyildiz; Erdal Cosgun; Gulay Uzun
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

8.  Effect of Different Denture Base Materials and Changed Mouth Temperature on Dimensional Stability of Complete Dentures.

Authors:  Khalid A O Arafa
Journal:  Int J Dent       Date:  2016-04-07
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.