Literature DB >> 1258796

Diastolic retroperfusion of acutely ischemic myocardium.

S Meerbaum, T W Lang, J V Osher, K Hashimoto, G W Lewis, C Feldstein, E Corday.   

Abstract

The effectiveness of coronary venous retroperfusion treatment of an ischemic myocardial segment was assessed by measurements of regional and global myocardial function in 16 dogs. The left anterior descending coronary artery was acutely occluded for 75 minutes. After the first 30 minutes of occlusion, diastolic retroperfusion was instituted for 45 minutes by synchronized pumping of arterial blood from the brachial artery into the anterior interventricular coronary vein. Data collected in the preocclusion control period, during occlusion and the subsequent retroperfusion period included simultaneous measurement os ischemic and border zone myocardial forces, epicardial electrocardiographic S-T segments, intracoronary pressure, coronary blood flow and oxygen pressure (PO2) sampled distal to the site of occlusion. Retroperfusion resulted in significant improvement from the level of regional dysfunction observed after 30 minutes of occlusion: Ischemic zone myocardial force increased 106%, epicardial S-T elevation decreased 46%, normalized peripheral left anterior descending coronary arterial flow increased 50% and distal left anterior descending PO2 decreased 44%. These regional improvements were significant when compared with findings in an untreated series of 12 dogs with 75 minutes occlusion of the left anterior descending coronary artery. Diastolic-augmented coronary venous retroperfusion with arterial blood provided significant but not complete restoration of function in the ischemic segment. Therefore, in the earliest phase of acute myocardial infarction, retroperfusion might represent a useful temporary support to an otherwise inaccessible jeopardized zone of the heart. Regional retroperfusion may constitute an effective emergency procedure, particularly when the occlusive lesions are diffuse and other medical or surgical emergency procedures are inadvisable, unavailable or ineffective.

Entities:  

Mesh:

Year:  1976        PMID: 1258796     DOI: 10.1016/0002-9149(76)90400-8

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  5 in total

Review 1.  Coronary Sinus Stent: Could It Help in Refractory Chronic Stable Angina?

Authors:  Wael ElMallah
Journal:  Curr Cardiol Rep       Date:  2016-04       Impact factor: 2.931

2.  Haemodynamic observations during percutaneous transluminal coronary angioplasty in the presence of synchronised diastolic coronary sinus retroperfusion.

Authors:  K J Beatt; P W Serruys; P de Feyter; M van den Brand; P D Verdouw; P G Hugenholtz
Journal:  Br Heart J       Date:  1988-02

3.  Effect of coronary sinus diastolic balloon pulsation on ischemic myocardium.

Authors:  S Canbaz; F Kolbakir; H T Keçelıgıl; Z Demır; M K Erk
Journal:  Exp Clin Cardiol       Date:  2001

4.  Refinement of pig retroperfusion technique: Global retroperfusion with ligation of the azygos connection preserves hemodynamic function in an acute infarction model in pigs (Sus scrofa domestica).

Authors:  Frank Harig; Evelyn Hoyer; Dirk Labahn; Joachim Schmidt; Michael Weyand; Stephan M Ensminger
Journal:  Comp Med       Date:  2010-02       Impact factor: 0.982

5.  A METHOD OF CORONARY RETROPERFUSION FOR THE TREATMENT OF ACUTE MYOCARDIAL ISCHEMIA.

Authors:  Mario Feola; Leslie Wiener
Journal:  Cardiovasc Dis       Date:  1978-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.