Literature DB >> 12587905

Stereotactic imaging for radiotherapy: accuracy of CT, MRI, PET and SPECT.

Christian P Karger1, Peter Hipp, Marcus Henze, Gernot Echner, Angelika Höss, Lothar Schad, Günther H Hartmann.   

Abstract

CT, MRI, PET and SPECT provide complementary information for treatment planning in stereotactic radiotherapy. Stereotactic correlation of these images requires commissioning tests to confirm the localization accuracy of each modality. A phantom was developed to measure the accuracy of stereotactic localization for CT, MRI, PET and SPECT in the head and neck region. To this end. the stereotactically measured coordinates of structures within the phantom were compared with their mechanically defined coordinates. For MRI, PET and SPECT, measurements were performed using two different devices. For MRI, T1- and T2-weighted imaging sequences were applied. For each measurement, the mean radial deviation in space between the stereotactically measured and mechanically defined position of target points was determined. For CT, the mean radial deviation was 0.4 +/- 0.2 mm. For MRI, the mean deviations ranged between 0.7 +/- 0.2 mm and 1.4 +/- 0.5 mm, depending on the MRI device and the imaging sequence. For PET, mean deviations of 1.1 +/- 0.5 mm and 2.4 +/- 0.3 mm were obtained. The mean deviations for SPECT were 1.6 +/- 0.5 mm and 2.0 +/- 0.6 mm. The phantom is well suited to determine the accuracy of stereotactic localization with CT, MRI, PET and SPECT in the head and neck region. The obtained accuracy is well below the physical resolution for CT, PET and SPECT, and of comparable magnitude for MRI. Since the localization accuracy may be device dependent, results obtained at one device cannot be generalized to others.

Mesh:

Year:  2003        PMID: 12587905     DOI: 10.1088/0031-9155/48/2/305

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Complementary role of helical CT cholangiography to MR cholangiography in the evaluation of biliary function and kinetics.

Authors:  Eleni Eracleous; Marios Genagritis; Nicos Papanikolaou; Allayioti Maria Kontou; P Prassopoullos; Haris Chrysikopoulos; Paul Allan; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2005-06-08       Impact factor: 5.315

2.  Impact of MRI timing on tumor volume and anatomic displacement for brain metastases undergoing stereotactic radiosurgery.

Authors:  Tugce Kutuk; Ranjini Tolakanahalli; Andre Williams; Martin C Tom; Jason D Vadhan; Haley Appel; Matthew D Hall; D Jay J Wieczorek; Stephen Davis; Michael W McDermott; Manmeet S Ahluwalia; Minesh P Mehta; Alonso N Gutierrez; Rupesh Kotecha
Journal:  Neurooncol Pract       Date:  2021-07-28

3.  A nanocomposite of Au-AgI core/shell dimer as a dual-modality contrast agent for x-ray computed tomography and photoacoustic imaging.

Authors:  Anamaria Orza; Yi Yang; Ting Feng; Xueding Wang; Hui Wu; Yuancheng Li; Lily Yang; Xiangyang Tang; Hui Mao
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

4.  Simultaneous CT-MRI Reconstruction for Constrained Imaging Geometries Using Structural Coupling and Compressive Sensing.

Authors:  Yan Xi; Jun Zhao; James R Bennett; Mitchel R Stacy; Albert J Sinusas; Ge Wang
Journal:  IEEE Trans Biomed Eng       Date:  2015-12-09       Impact factor: 4.538

5.  A standardized method for the construction of tracer specific PET and SPECT rat brain templates: validation and implementation of a toolbox.

Authors:  David Vállez Garcia; Cindy Casteels; Adam J Schwarz; Rudi A J O Dierckx; Michel Koole; Janine Doorduin
Journal:  PLoS One       Date:  2015-03-30       Impact factor: 3.240

6.  In vivo localization of chronically implanted electrodes and optic fibers in mice.

Authors:  Bálint Király; Diána Balázsfi; Ildikó Horváth; Nicola Solari; Katalin Sviatkó; Katalin Lengyel; Eszter Birtalan; Magor Babos; Gergő Bagaméry; Domokos Máthé; Krisztián Szigeti; Balázs Hangya
Journal:  Nat Commun       Date:  2020-09-17       Impact factor: 14.919

Review 7.  Current concepts in stereotactic radiosurgery - a neurosurgical and radiooncological point of view.

Authors:  Jan Vesper; B Bölke; C Wille; P A Gerber; C Matuschek; M Peiper; H J Steiger; W Budach; G Lammering
Journal:  Eur J Med Res       Date:  2009-03-17       Impact factor: 2.175

8.  Volumetric accuracy of cone-beam computed tomography.

Authors:  Cheol-Woo Park; Jin-Ho Kim; Yu-Kyeong Seo; Sae-Rom Lee; Ju-Hee Kang; Song-Hee Oh; Gyu-Tae Kim; Yong-Suk Choi; Eui-Hwan Hwang
Journal:  Imaging Sci Dent       Date:  2017-09-21
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.