Reteplase for dysfunctional hemodialysis catheter clearance.

Daniel E Hilleman1, Robert W Dunlay, Kathleen A Packard.   

Abstract

STUDY
OBJECTIVE: To evaluate the efficacy of reteplase administration in clearing hemodialysis catheters.
DESIGN: Open-label, uncontrolled, observational trial.
SETTING: University medical center. PATIENTS: Thirty-four patients with end-stage renal disease undergoing long-term hemodialysis. INTERVENTION: Patients had dual-lumen, cuffed, tunneled dialysis catheters placed for long-term vascular access. Reteplase 3 U was instilled into each catheter lumen (total dose 6 U) in the first 20 episodes, 2 U in each catheter lumen (total dose 4 U) in the next 20, and 0.5 U in each catheter lumen (total dose 1 U) in the final 45.
MEASUREMENTS AND MAIN RESULTS: Over 12 months, 85 episodes of catheter dysfunction were documented. Catheter dysfunction was defined as absence of flow from the catheter lumen, inability to aspirate heparin from the lumen, blood flow rates below 150 ml/minute, or venous pressure greater than 250 mm Hg at blood flow rates below 200 ml/minute. Reteplase was instilled into the catheter lumens and allowed to dwell there until the next hemodialysis session. Successful catheter recanalization was defined as return of aspiration and infusion function allowing dialysis to be completed at blood flow rates above 300 ml/minute. Reteplase restored catheter function in 74 (87%) instances of catheter dysfunction. In the first 40 episodes in which 4- or 6-U doses were given, catheter function was restored in 36 instances (90%). There was no difference in restoration of catheter function between 4 U (18/20, 90%) and 6 U (18/20, 90%). In the last 45 cases in which 1 U was administered, function was restored in 38 catheters (84%). Mean overall dwell times were not different between the first 40 (32 +/- 7 hrs) and the last 45 episodes (33 +/- 10 hrs). The overall mean duration of catheter patency was 45 +/- 39 days. Durations of patency in the three dose groups were not significantly different (44 +/- 38, 46 +/- 40, 45 +/- 39 days). No patient suffered adverse effects related to reteplase.
CONCLUSION: Reteplase installation in dysfunctional hemodialysis catheters was effective in restoring catheter function in 87% of episodes. A dose of 1 U appears to be as effective as 4 and 6 U.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12587800     DOI: 10.1592/phco.23.2.137.32086

Source DB:  PubMed          Journal:  Pharmacotherapy        ISSN: 0277-0008            Impact factor:   4.705


  6 in total

1.  K/DOQI Guidelines: What Should an Interventionalist Know?

Authors:  Aalpen A Patel; Catherine M Tuite; Scott O Trerotola
Journal:  Semin Intervent Radiol       Date:  2004-06       Impact factor: 1.513

2.  Improvement of hemodialysis catheter function with tenecteplase: a phase III, open-label study: TROPICS 4.

Authors:  Steven Fishbane; Samuel L Milligan; Kenneth D Lempert; Joachim E W Hertel; James B Wetmore; Matthew J Oliver; Martha Blaney; Barbara S Gillespie; Joan R Jacobs; Susan M Begelman
Journal:  J Thromb Thrombolysis       Date:  2011-01       Impact factor: 2.300

3.  Recombinant tissue plasminogen activator infusion for hemodialysis catheter clearance.

Authors:  Oluwatoyin F Bamgbola; Marcela del Rio; Frederick J Kaskel; Joseph T Flynn
Journal:  Pediatr Nephrol       Date:  2005-04-21       Impact factor: 3.714

4.  A phase III, randomized, double-blind, placebo-controlled study of tenecteplase for improvement of hemodialysis catheter function: TROPICS 3.

Authors:  James Tumlin; Jesse Goldman; David M Spiegel; David Roer; K Adu Ntoso; Martha Blaney; Joan Jacobs; Barbara S Gillespie; Susan M Begelman
Journal:  Clin J Am Soc Nephrol       Date:  2010-02-04       Impact factor: 8.237

Review 5.  Reevaluation of lock solutions for Central venous catheters in hemodialysis: a narrative review.

Authors:  Yiqin Wang; Xuefeng Sun
Journal:  Ren Fail       Date:  2022-12       Impact factor: 3.222

6.  Use of tissue plasminogen activator in catheters used for extracorporeal renal replacement therapy.

Authors:  C Langston; A Eatroff; K Poeppel
Journal:  J Vet Intern Med       Date:  2014-01-17       Impact factor: 3.333

  6 in total