| Literature DB >> 12586538 |
Massimo Corradi1, Alberto Pesci, Romano Casana, Rossella Alinovi, Matteo Goldoni, Maria Vittoria Vettori, Angelo Cuomo.
Abstract
There is an increasing interest in the measurement of nitric oxide (NO.) in the airways. NO. is a free radical that reacts rapidly with reactive oxygen species in aqueous solution to form peroxynitrite which can then break down to nitrite (NO(2)(-)) and nitrate (NO(3)(-)). NO(3)(-) is considered a stable oxidative end product of NO. metabolism. The aim of this study was to assay NO(3)(-) in exhaled breath condensate (EBC) of normal nonsmoking and smoking subjects, asthmatics, patients with obstructive pulmonary disease (COPD), and patients with community-acquired pneumonia (CAP). EBC was collected using a glass condenser and samples were assayed for NO(3)(-) by ion chromatography followed by conductivity measurement. NO(3)(-) was detectable in EBC of all subjects. NO(3)(-) was elevated in smokers [median (range)] [62.5 (9.6-158.0) microM] and in asthmatics [68.0 (25.8-194.6) microM] compared to controls [9.6 (2.6-119.4) microM; p=0.003 and p=0.006, respectively], whereas NO(3)(-) was not elevated in COPD patients [24.1 (1.9-337.0 microM]. The concentration of NO(3)(-) in patients with CAP [243.4 (26.1-584.5) microM] was higher than that in controls (p=0.002) and NO(3)(-) values decreased after treatment and recovery from illness [40.0 (4.1-167.0) microM, p=0.009]. This study shows that NO(3)(-) is detectable in EBC of healthy subjects and it varies in patients with inflammatory airway diseases.Entities:
Mesh:
Substances:
Year: 2003 PMID: 12586538 DOI: 10.1016/s1089-8603(02)00128-3
Source DB: PubMed Journal: Nitric Oxide ISSN: 1089-8603 Impact factor: 4.427