The validity of clinical examination in the diagnosis of loosening of components in total hip arthroplasty.

C Röder1, S Eggli, M Aebi, A Busato.   

Abstract

We analysed follow-up data from 18,486 primary total hip arthroplasties performed between 1967 and 2001 to assess the validity of clinical procedures in diagnosing loosening of prosthetic components. Sensitivity, specificity and predictive values were estimated with the radiological definition of loose or not loose as the 'gold standard'. The prevalence of acetabular loosening increased from 0.6% to 13.9% during the period of the study and that of femoral loosening from 0.9% to 12.1%. Sensitivities and positive predictive values were low, suggesting that clinical procedures could not replace radiological assessment in the identification of loose prostheses. Specificities and negative predictive values were constantly above 0.86. The possibility of there being a prosthesis which is not loose in asymptomatic patients was consequently very high, particularly during the first five to six years after operation. The necessity of periodic clinical and radiological follow-up examinations of asymptomatic patients during the first five to six years after operation remains questionable. Symptomatic patients, however, require radiological assessment.

Entities:  

Mesh:

Year:  2003        PMID: 12585575     DOI: 10.1302/0301-620x.85b1.13367

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  9 in total

Review 1.  The International Documentation and Evaluation System (IDES)--10-years experience.

Authors:  C Röder; S Eggli; A EL-Kerdi; U Müller; T Ambrose; E Röösli; A Busato; M Aebi
Journal:  Int Orthop       Date:  2003-08-07       Impact factor: 3.075

2.  Acetabular Defect Reconstruction with Trabecular Metal Augments: Study with Minimum One-year Follow-up.

Authors:  Chirayu Dwivedi; Sandeep Gokhale; Hyun Gon Khim; Jeon Keon Oh; Won Yong Shon
Journal:  Hip Pelvis       Date:  2017-09-06

3.  Use of morphometry to quantify osteolysis after total hip arthroplasty.

Authors:  Lindsay K Smith; Fiona Cramp; Shea Palmer; Nikki Coghill; Robert F Spencer
Journal:  Clin Orthop Relat Res       Date:  2010-05-12       Impact factor: 4.176

4.  Flow cytometry as a diagnostic tool for identifying total hip arthroplasty loosening and differentiating between septic and aseptic cases.

Authors:  Maria Ovrenovits; Emilios E Pakos; Georgios Vartholomatos; Nikolaos K Paschos; Theodoros A Xenakis; Grigorios I Mitsionis
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-07-12

5.  Combined use of low-intensity pulsed ultrasound and rhBMP-2 to enhance bone formation in a rat model of critical size defect.

Authors:  Siddhesh R Angle; Kotaro Sena; Dale R Sumner; Walter W Virkus; Amarjit S Virdi
Journal:  J Orthop Trauma       Date:  2014-10       Impact factor: 2.512

6.  Body mass characteristics of hip osteoarthritis patients experiencing aseptic loosening, periprosthetic fractures, dislocation, and infections after total hip replacement.

Authors:  Ray Marks
Journal:  Clinicoecon Outcomes Res       Date:  2009-05-15

Review 7.  Dutch guideline on total hip prosthesis.

Authors:  Bart A Swierstra; Anton M J S Vervest; Geert H I M Walenkamp; B Wim Schreurs; Pieter T J Spierings; Ide C Heyligers; Job L C van Susante; Harmen B Ettema; Mariette J Jansen; Pim J Hennis; Janneke de Vries; Sabrina B Muller-Ploeger; Margreet A Pols
Journal:  Acta Orthop       Date:  2011-10       Impact factor: 3.717

8.  The course of radiographic loosening, pain and functional outcome around the first revision of a total hip arthroplasty.

Authors:  Emin Aghayev; Regula Teuscher; Michal Neukamp; Eu Jin Lee; Markus Melloh; Stefan Eggli; Christoph Röder
Journal:  BMC Musculoskelet Disord       Date:  2013-05-15       Impact factor: 2.362

Review 9.  A systematic review of the diagnostic performance of orthopedic physical examination tests of the hip.

Authors:  Labib Ataur Rahman; Sam Adie; Justine Maree Naylor; Rajat Mittal; Sarah So; Ian Andrew Harris
Journal:  BMC Musculoskelet Disord       Date:  2013-08-30       Impact factor: 2.362

  9 in total