Literature DB >> 12585480

Application of diamond microelectrodes for end-column electrochemical detection in capillary electrophoresis.

Dongchan Shin1, Bulusu V Sarada, Donald A Tryk, Akira Fujishima, Joseph Wang.   

Abstract

Highly boron-doped diamond microelectrodes were employed in an end-column electrochemical detector for capillary electrophoresis (CE). The diamond microline electrodes were fabricated from conducting diamond thin films (exposed surface area, 300 x 50 microm), and their analytical performance as CE detectors was evaluated in a laboratory-made CE installation. The CE-ED system exhibited high separation efficiency for the detection of several catecholamines, including dopamine (DA), norepinephrine (NE), and epinephrine (E), with excellent analytical performance, for example, 155,000 theoretical plates for DA. The diamond-based electrochemical detection system also displayed low detection limits (approximately 20 nM for E at S/N = 3) and a highly reproducible current response with 10 repetitive injections of mixed analytes containing DA, NE, and E (each 50 microM), with relative standard deviations (RSD) of approximately 5%. The performance of the diamond detector in CE was also evaluated in the detection of chlorinated phenols (CP). When compared to the carbon fiber microelectrode, the diamond electrode exhibited lower detection limits in an end-column CE detection resulting from very low noise levels and highly reproducible analyses without electrode polishing due to analyte fouling, which makes it possible to perform easier and more stable CE analysis.

Entities:  

Year:  2003        PMID: 12585480     DOI: 10.1021/ac020513j

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  Boron-doped diamond nano/microelectrodes for biosensing and in vitro measurements.

Authors:  Hua Dong; Shihua Wang; James J Galligan; Greg M Swain
Journal:  Front Biosci (Schol Ed)       Date:  2011-01-01

2.  Polycrystalline-Diamond MEMS Biosensors Including Neural Microelectrode-Arrays.

Authors:  Michael W Varney; Dean M Aslam; Abed Janoudi; Ho-Yin Chan; Donna H Wang
Journal:  Biosensors (Basel)       Date:  2011-08-15

3.  An effective method to improve the growth rate of large single crystal diamonds under HPHT processes: optimized design of the catalyst geometric construction.

Authors:  Yadong Li; Chunxiao Wang; Liangchao Chen; Longsuo Guo; Zhuangfei Zhang; Chao Fang; Hongan Ma
Journal:  RSC Adv       Date:  2019-10-09       Impact factor: 3.361

4.  Multichannel boron doped nanocrystalline diamond ultramicroelectrode arrays: design, fabrication and characterization.

Authors:  Raphael Kiran; Lionel Rousseau; Gaëlle Lissorgues; Emmanuel Scorsone; Alexandre Bongrain; Blaise Yvert; Serge Picaud; Pascal Mailley; Philippe Bergonzo
Journal:  Sensors (Basel)       Date:  2012-06-07       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.