Literature DB >> 12581846

Three-dimensional load analysis of indentation stimulators.

Geoffrey M Bove1, Daniel R Robichaud, Peter Grigg.   

Abstract

The properties of three types of indentation stimulators: filament indenters, a spring gauge indenter, and an electromechanical stimulator, were evaluated by actuating each device against a 3-direction load cell. The on-axis loads produced by filament indenters were independent of the degree of buckling. The off-axis loads produced by a filament increased with the degree of buckling of the filament, and had magnitudes that were up to 25% of the on-axis load. Repeated applications of a filament produced loads whose magnitudes were very consistent. Offsetting the handle of a filament indenter altered the magnitude and the direction of the off-axis load. Because these factors were poorly controlled in hand held trials, off-axis loads were more variable in hand held trials. The spring gauge stimulator was, when hand held, very susceptible to creating large off-axis loads. When the off-axis loads were large, the spring gauge indicator underestimated the true on-axis loads. The electromechanical stimulator produced loads with a very high degree of consistency and could be arranged so that it produced very small off-axis loads.

Mesh:

Year:  2003        PMID: 12581846     DOI: 10.1016/s0165-0270(02)00326-6

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  3 in total

1.  A Multivariate Logistical Model for Identifying the Compressive Sensitivity of Single Rat Tactile Receptors as Nanobiosensors.

Authors:  Sean S Kohles; Sam Bradshaw; Shelley S Mason; Fred J Looft
Journal:  J Nanotechnol Eng Med       Date:  2011-02-01

2.  Pain after spinal cord injury: an evidence-based review for clinical practice and research. Report of the National Institute on Disability and Rehabilitation Research Spinal Cord Injury Measures meeting.

Authors:  Thomas N Bryce; Cecilia Norrbrink Budh; Diana D Cardenas; Marcel Dijkers; Elizabeth R Felix; Nanna B Finnerup; Paul Kennedy; Thomas Lundeberg; J Scott Richards; Diana H Rintala; Philip Siddall; Eva Widerstrom-Noga
Journal:  J Spinal Cord Med       Date:  2007       Impact factor: 1.985

3.  A feedback-controlled dynamic linear actuator to test foot withdrawal thresholds in rat.

Authors:  P Grigg; D R Robichaud; G M Bove
Journal:  J Neurosci Methods       Date:  2007-02-16       Impact factor: 2.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.