An ocular pneumoplethysmograph was devised to measure the systolic pressure in the ophthalmic artery and to obtain calibrated pulse volume changes from the ocular globe, with simultaneous recording from both eyes. The instrument is self-contained and portable. It can be applied by paramedical personnel, and the graphic recording is readily interpreted by the physician. It has proved to be 100% accurate in noninvasively detecting unilateral carotid occlusion or preocclusive stenosis. This technique, when combined with carotid compression, has been shown to be most valuable in assessing the tolerance of a cerebral hemisphere to proximal carotid occlusion. It was used to evaluate a wide variety of carotid arterial lesions. Elective carotid resection without graft replacement and urgent and elective carotid ligations were performed, based on the preoperative prediction that such procedures would be tolerated without neurological injury. The instrument and the technique of its application are simple, safe, and accurate.

Entities:  

Mesh:

Year:  1976        PMID: 1258100     DOI: 10.1161/01.str.7.1.18

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  12 in total

Review 1.  Extracranial vascular disease: advances in operative indications and technique.

Authors:  A M Imparato
Journal:  World J Surg       Date:  1988-12       Impact factor: 3.352

2.  Retinal fluorotachometry. A clinically applicable method of retinal flow measurement.

Authors:  A V Schulte
Journal:  Doc Ophthalmol       Date:  1987-02       Impact factor: 2.379

3.  New techniques in the evaluation of cerebrovascular disease.

Authors:  S N Carson; F W Blaisdell
Journal:  West J Med       Date:  1979-11

4.  Carotid Doppler evaluation in cerebrovascular disease.

Authors:  J G D'Alton; J W Norris
Journal:  Can Med Assoc J       Date:  1983-12-01       Impact factor: 8.262

5.  Autoregulation of ocular blood flow during changes in intraocular pressure. Preliminary results.

Authors:  L E Pillunat; R Stodtmeister; I Wilmanns; T Christ
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1985       Impact factor: 3.117

6.  Functional anatomy of extracranial arteries in occlusive vascular diseases by direct continuous wave Doppler sonography.

Authors:  H C Diener; J Dichgans; K Voigt
Journal:  Cardiovasc Intervent Radiol       Date:  1981       Impact factor: 2.740

Review 7.  Strokes, transient ischemic attacks and asymptomatic bruits.

Authors:  H I Machleder
Journal:  West J Med       Date:  1979-03

8.  Ocular pneumoplethysmography: detection of carotid occlusive disease.

Authors:  P T McDonald; N M Rich; G J Collins; L Kozloff; C A Andersen
Journal:  Ann Surg       Date:  1979-01       Impact factor: 12.969

9.  Diagnosis of carotid artery stenosis: comparison of oculoplethysmography and Doppler supraorbital examination.

Authors:  J M Malone; B Bean; J Laguna; R Hamilton; E Labadie; W S Moore
Journal:  Ann Surg       Date:  1980-03       Impact factor: 12.969

10.  What measurements are necessary for a comprehensive evaluation of the peripheral arterial circulation?

Authors:  Robert S. Reneman
Journal:  Cardiovasc Dis       Date:  1981-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.