Intraocular pressure control and complications with two-stage insertion of the Baerveldt implant.

Ly Tong1, Karys Frazao, Laurie LaBree, Rohit Varma.   

Abstract

PURPOSE: To evaluate intraocular pressure (IOP) control and the prevalence of complications associated with the two-stage insertion of the Baerveldt implant.
DESIGN: Retrospective, noncomparative, interventional case series.
METHODS: We reviewed the medical records of all patients who underwent the two-stage Baerveldt implantation for advanced glaucoma between January 1995 and November 1998 at the Doheny Eye Institute, Los Angeles, California. All eyes with a minimum of 6 months of follow-up were included in the study. Eyes that failed before 6 months after stage II were also included in the study. MAIN OUTCOME MEASURES: The criterion for surgical success was postoperative IOP of 6 mmHg or more and 21 mmHg or less on two or more consecutive measurements with or without the use of glaucoma medications and without loss of light perception or further surgical intervention to lower IOP.
RESULTS: Nineteen eyes from 19 patients were included. Median postoperative follow-up was 17 months (range, 3-56 months). The cumulative probability of success was 89% at both 12 and 24 months. The median preoperative IOP of 21 mmHg (range, 12-33 mmHg) was reduced to a median postoperative IOP of 12 mmHg (range, 1-17 mmHg; P < 0.0001). The median number of glaucoma medications before surgery was three and after surgery was one (P < 0.0001). Visual acuity remained the same or improved in 13 eyes (68%). One eye experienced hypotony (5%), and in two eyes (11%) suprachoroidal hemorrhages developed.
CONCLUSIONS: The two-stage insertion of the Baerveldt implant effectively reduced IOP, produced few complications, and preserved visual acuity in more than two thirds of eyes with advanced glaucomatous damage.

Entities:  

Mesh:

Year:  2003        PMID: 12578780     DOI: 10.1016/S0161-6420(02)01752-9

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  3 in total

1.  Intraocular pressure control of a novel glaucoma drainage device - in vitro and in vivo studies.

Authors:  Li-Jun Cui; Di-Chen Li; Jian Liu; Lei Zhang; Yao Xing
Journal:  Int J Ophthalmol       Date:  2017-09-18       Impact factor: 1.779

2.  Longitudinal rates of postoperative adverse outcomes after glaucoma surgery among medicare beneficiaries 1994 to 2005.

Authors:  Joshua D Stein; David Ruiz; Daniel Belsky; Paul P Lee; Frank A Sloan
Journal:  Ophthalmology       Date:  2008-07       Impact factor: 12.079

3.  Fluid Dynamics of Small Diameter Tubes Used in Membrane-tube Type Glaucoma Shunt Devices.

Authors:  Jong Chul Han; Young Hoon Hwang; Byung Heon Ahn
Journal:  Korean J Ophthalmol       Date:  2019-08
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.