Literature DB >> 12578213

Investigations on the wear behaviour of the temporary PMMA-based hip Spacer-G.

S Affatato1, A Mattarozzi, P Taddei, P Robotti, R Soffiatti, A Sudanese, A Toni.   

Abstract

Total hip replacement has become one of the most successful orthopaedic procedures. However, complications due to infections may give serious problems and have devastating consequences for the hip implant. The use of a temporary three-dimensional polymethylmethacrylate (PMMA) cement spacer may be an alternative to solve infections in hip implants, improving the lives of patients awaiting reimplantation. In order to evaluate their wear behaviour, five PMMA Spacer-G femoral heads were tested against five post-mortem pelves in a hip joint simulator with bovine calf serum as lubricant. The surface of the worn spacers was characterized by scanning electron microscopy (SEM) analysis; all the samples revealed a similar morphology, showing areas characterized by different degrees of wear. Particle debris was isolated from the lubricant and PMMA particles and bone fractions were quantified. The amount of debris was found to be higher than where no-temporary prostheses were used. However, this result is acceptable since wear debris is removed by lavage irrigation when the Spacer-G is explanted. On the basis of these data, it is considered that the use of the cement Spacer-G could be a promising approach to the treatment of complicated infections of the hip joint. Therefore, Spacer-G is worthy of further research.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12578213     DOI: 10.1243/095441103762597665

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  7 in total

1.  A technique for the fabrication of a reinforced moulded articulating cement spacer in two-stage revision total hip arthroplasty.

Authors:  Matthew Kent; Rajesh Rachha; Manoj Sood
Journal:  Int Orthop       Date:  2009-08-20       Impact factor: 3.075

2.  Two-stage revision surgery with preformed spacers and cementless implants for septic hip arthritis: a prospective, non-randomized cohort study.

Authors:  Carlo L Romanò; Delia Romanò; Enzo Meani; Nicola Logoluso; Lorenzo Drago
Journal:  BMC Infect Dis       Date:  2011-05-16       Impact factor: 3.090

3.  The use of a preformed spacer in two-stage revision of infected hip arthroplasties.

Authors:  F D'Angelo; L Negri; T Binda; G Zatti; P Cherubino
Journal:  Musculoskelet Surg       Date:  2011-04-09

4.  Articulating spacers used in two-stage revision of infected hip and knee prostheses abrade with time.

Authors:  Bernd Fink; Annett Rechtenbach; Hubert Büchner; Sebastian Vogt; Michael Hahn
Journal:  Clin Orthop Relat Res       Date:  2010-07-28       Impact factor: 4.176

5.  Wear Performance of Calcium Carbonate-Containing Knee Spacers.

Authors:  Ulrike Mueller; Joern Reinders; Sydney Smith-Romanski; Jan Philippe Kretzer
Journal:  Materials (Basel)       Date:  2017-07-15       Impact factor: 3.623

6.  Evaluation of the standard procedure for the treatment of periprosthetic joint infections (PJI) in Germany - results of a survey within the EndoCert initiative.

Authors:  Christina Rimke; Andreas Enz; Hermann Josef Bail; Peter Heppt; Bernd Kladny; Gabriela von Lewinski; Christoph H Lohmann; Katrin Osmanski-Zenk; Holger Haas; Wolfram Mittelmeier
Journal:  BMC Musculoskelet Disord       Date:  2020-10-19       Impact factor: 2.362

7.  Mechanical behaviour of standardized, endoskeleton-including hip spacers implanted into composite femurs.

Authors:  T Thielen; S Maas; A Zuerbes; D Waldmann; K Anagnostakos; J Kelm
Journal:  Int J Med Sci       Date:  2009-09-03       Impact factor: 3.738

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.