Literature DB >> 12578133

A novel beamformer design method for medical ultrasound. Part I: Theory.

Karthik Ranganathan1, William F Walker.   

Abstract

The design of transmit and receive aperture weightings is a critical step in the development of ultrasound imaging systems. Current design methods are generally iterative, and consequently time consuming and inexact. We describe a new and general ultrasound beamformer design method, the minimum sum squared error (MSSE) technique. The MSSE technique enables aperture design for arbitrary beam patterns (within fundamental limitations imposed by diffraction). It uses a linear algebra formulation to describe the system point spread function (psf) as a function of the aperture weightings. The sum squared error (SSE) between the system psf and the desired or goal psf is minimized, yielding the optimal aperture weightings. We present detailed analysis for continuous wave (CW) and broadband systems. We also discuss several possible applications of the technique, such as the design of aperture weightings that improve the system depth of field, generate limited diffraction transmit beams, and improve the correlation depth of field in translated aperture system geometries. Simulation results are presented in an accompanying paper.

Mesh:

Year:  2003        PMID: 12578133     DOI: 10.1109/tuffc.2003.1176522

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  8 in total

1.  Imaging with unfocused regions of focused ultrasound beams.

Authors:  Roger Zemp; Michael F Insana
Journal:  J Acoust Soc Am       Date:  2007-03       Impact factor: 1.840

2.  A method for accurate in silico modeling of ultrasound transducer arrays.

Authors:  Drake A Guenther; William F Walker
Journal:  Ultrasonics       Date:  2008-10-30       Impact factor: 2.890

3.  Simultaneous Axial Multifocal Imaging Using a Single Acoustical Transmission: A Practical Implementation.

Authors:  Asaf Ilovitsh; Tali Ilovitsh; Josquin Foiret; Douglas N Stephens; Katherine W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-05       Impact factor: 2.725

4.  Magnetoacoustic tomography with magnetic induction for high-resolution bioimepedance imaging through vector source reconstruction under the static field of MRI magnet.

Authors:  Leo Mariappan; Gang Hu; Bin He
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

5.  Magnetoacoustic tomography with magnetic induction: bioimepedance reconstruction through vector source imaging.

Authors:  Leo Mariappan; Bin He
Journal:  IEEE Trans Med Imaging       Date:  2013-01-11       Impact factor: 10.048

6.  Determination of lateral modulation apodization functions using a regularized, weighted least squares estimation.

Authors:  Chikayoshi Sumi
Journal:  Int J Biomed Imaging       Date:  2010-05-09

7.  Magneto acoustic tomography with short pulsed magnetic field for in-vivo imaging of magnetic iron oxide nanoparticles.

Authors:  Leo Mariappan; Qi Shao; Chunlan Jiang; Kai Yu; Shai Ashkenazi; John C Bischof; Bin He
Journal:  Nanomedicine       Date:  2015-12-02       Impact factor: 5.307

8.  Imaging beyond ultrasonically-impenetrable objects.

Authors:  Tali Ilovitsh; Asaf Ilovitsh; Josquin Foiret; Katherine W Ferrara
Journal:  Sci Rep       Date:  2018-04-10       Impact factor: 4.379

  8 in total