Longitudinal aliasing in multislice helical computed tomography: sampling and cone-beam effects.

Patrick J La Rivière1, Xiaochuan Pan.   

Abstract

In this study, we examine longitudinal aliasing properties in multislice helical computed tomography (CT) volumes reconstructed under the multiple parallel fanbeam approximation by use of a 180LI-type algorithm. We focus on the differences between the multislice case and the single-slice case, which has been studied previously. Specifically, we examine longitudinal aliasing properties in four-slice scanners for helical pitches 3 and 6, which are sometimes called "preferred" in four-slice helical CT, because it is believed that the effective longitudinal sampling intervals at these pitches are equivalent to those in single-slice helical CT operating at pitches 1 and 2, respectively. While these equivalences have been supported by comparative studies of slice-sensitivity profiles in single- and multislice helical CT, artifacts have been observed in pitch-3 and pitch-6 multislice images that were not evident in their purported single-slice counterparts. We attribute these differences to aliasing arising in the multislice reconstructions that is not present in the single-slice counterparts. We find that the aliasing has two principal origins: sampling effects similar to those in the single-slice case and cone-beam effects. The difference between the multislice, pitch-3 and single-slice, pitch-1 results is attributed to the small cone angle in multislice helical CT, which introduces inconsistencies among the measurements of different detector rows. The difference between multislice, pitch-6 and single-slice, pitch-2 results is attributed to a combination of the cone angle and genuine differences in sampling patterns. It is argued, however, that the lack of strict equivalence with single-slice counterparts does not necessarily undermine the claim that pitches 3 and 6 are "preferred" relative to other pitches in multislice helical CT.

Mesh:

Year:  2002        PMID: 12575873     DOI: 10.1109/TMI.2002.806428

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  1 in total

1.  Comparison of different patient positioning strategies to minimize shoulder girdle artifacts in head and neck CT.

Authors:  Stefan Wirth; Thomas Meindl; Marcus Treitl; Klaus-Jürgen Pfeifer; Maximilian Reiser
Journal:  Eur Radiol       Date:  2006-03-17       Impact factor: 5.315

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.