Quantitative assay of hepatitis C virus RNA using an automated extraction system for specific capture with probes and paramagnetic particle separation.

Hayato Miyachi1, Atsuko Masukawa, Satomi Asai, Toshiaki Miura, Shigeru Tamatsukuri, Toru Hirose, Yasuhiko Ando.   

Abstract

A commercially available automated specimen preparation instrument for specific probe capture and paramagnetic separation has been developed (AmpliCap/GT-12; Roche Molecular Systems). We evaluated assay performance of the AmpliCap/GT-12 in the quantitative assay for hepatitis C virus (HCV) RNA with the AMPLICOR HCV MONITOR Test (version 2.0). Assay linearity using serial dilutions from a serum panel was observed in the range of 500 to 850000 IU/ml, with a slightly compromised slope in the higher viral titers. The overall within-run and between-run reproducibility of the entire detection process for 3 and 5 log(10) (IU/ml) of HCV RNA in samples had a standard deviation of <0.2, which was comparable to a manual method based on organic extraction and isopropanol precipitation (Roche Molecular Systems). Comparison of the test results with those obtained by the manual method showed a good correlation (R(2) = 0.972, n = 86). Using heparin (3, 6.5, and 13 U/ml), dextran sulfate (0.1, 1, and 5 mM), hemoglobin (1.13, 2.25, and 4.5 g/liter), conjugated or unconjugated bilirubin (7.5, 15, and 30 mg/dl), and ATP (1.25, 2.5, and 5.0 mM) as known inhibitors, inhibition was only detected at a dextran sulfate concentration of 1 mM with the manual method but not with the AmpliCap/GT-12 extraction. In summary, the AmpliCap/GT-12 system was shown to permit a stable extraction process and accurate results for the quantitative assay of HCV RNA, successfully eliminating the inhibitory effect of dextran sulfate. This automated extraction system provides reliable and reproducible test results and saves labor; thus, it is suitable for routine diagnostic PCR.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12574248      PMCID: PMC149669          DOI: 10.1128/JCM.41.2.572-575.2003

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  24 in total

1.  Tech.Sight. Molecular testing for infectious disease.

Authors:  D Jungkind
Journal:  Science       Date:  2001-11-16       Impact factor: 47.728

2.  [Inhibitory effects of therapeutic reagents on the PCR detection of hepatitis C virus in serum and their elimination by RNA extraction methods].

Authors:  A Masukawa; H Miyachi; T Ohshima; Y Ando
Journal:  Rinsho Byori       Date:  1999-10

3.  Automated specific capture of hepatitis C virus RNA with probes and paramagnetic particle separation.

Authors:  H Miyachi; A Masukawa; T Ohshima; T Hirose; C Impraim; Y Ando
Journal:  J Clin Microbiol       Date:  2000-01       Impact factor: 5.948

4.  Nationwide nucleic acid amplification testing of hepatitis B virus, hepatitis C virus and human immunodeficiency virus type 1 for blood transfusion and follow-up study of nucleic acid amplification positive donors.

Authors: 
Journal:  Jpn J Infect Dis       Date:  2000-06       Impact factor: 1.362

5.  Clinical evaluation of the automated COBAS AMPLICOR HCV MONITOR test version 2.0 for quantifying serum hepatitis C virus RNA and comparison to the quantiplex HCV version 2.0 test.

Authors:  M L Yu; W L Chuang; C Y Dai; S C Chen; Z Y Lin; M Y Hsieh; L Y Wang; W Y Chang
Journal:  J Clin Microbiol       Date:  2000-08       Impact factor: 5.948

Review 6.  Present treatment expectations and risks of chronic hepatitis C.

Authors:  V Carreño
Journal:  Clin Microbiol Infect       Date:  2002-02       Impact factor: 8.067

7.  Early detection of nonresponse to interferon plus ribavirin combination treatment of chronic hepatitis C.

Authors:  F J Castro; J I Esteban; A Juárez; S Sauleda; L Viladomiu; M Martell; F Moreno; H Allende; R Esteban; J Guardia
Journal:  J Viral Hepat       Date:  2002-05       Impact factor: 3.728

Review 8.  An introduction to nucleoside and nucleotide analogues.

Authors:  K E Squires
Journal:  Antivir Ther       Date:  2001

9.  Performance characteristics of the COBAS AMPLICOR hepatitis C virus MONITOR Test, version 2.0.

Authors:  M Erali; E R Ashwood; D R Hillyard
Journal:  Am J Clin Pathol       Date:  2000-08       Impact factor: 2.493

10.  Clinical application of the Quantiplex HCV RNA 2.0 and Amplicor HCV Monitor assays for quantifying serum hepatitis C virus RNA.

Authors:  M L Yu; W L Chuang; S C Chen; Z Y Lin; M Y Hsieh; L Y Wang; W Y Chang
Journal:  J Clin Pathol       Date:  1999-11       Impact factor: 3.411

View more
  2 in total

1.  The role of human metapneumovirus in upper respiratory tract infections in children: a 20-year experience.

Authors:  John V Williams; Chiaoyin K Wang; Chin-Fen Yang; Sharon J Tollefson; Frances S House; Josh M Heck; Marla Chu; Jennifer B Brown; Linda D Lintao; Joe D Quinto; David Chu; Richard R Spaete; Kathryn M Edwards; Peter F Wright; James E Crowe
Journal:  J Infect Dis       Date:  2005-12-30       Impact factor: 5.226

2.  Extraction of HCV-RNA from Plasma Samples: Development towards Semiautomation.

Authors:  Imran Amin; Tania Jabbar; Fawad Niazi; Muhammad Saeed Akhtar
Journal:  Int J Anal Chem       Date:  2015-03-19       Impact factor: 1.885

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.