Literature DB >> 12573789

Reducing inter-observer variation in thyroid volume calculation using a new formula and technique.

Wael Shabana1, Els Peeters, Peter Verbeek, Michel M Osteaux.   

Abstract

OBJECTIVE: Ultrasound (US) measurement of thyroid volume is used in diagnosis and follow-up of patients with thyroid disease. We assessed a new formula and technique for thyroid volume calculation, based on an automatically continuous trace transverse surface area (aTSA) calculation, to ascertain where this technique could reduce inter-observer variation.
METHODS: Three observers with a different level of US expertise, using a 12-5 MHz linear transducer, examined 25 volunteers. Inter-observer variations were calculated for diameter measurements and for the thyroid lobe volume calculations using the single factor ANOVA method.
RESULTS: Using the new technique and formula, no statistically significant differences existed, in contradistinction to using the classical formula for an ellipsoid (P=0.02).
CONCLUSION: When thyroid volume measurements are required, we recommend using a new method of thyroid volume calculation based on the use of an automatically calculated continuous trace aTSA measurement to avoid significant inter-observer variation in calculation of thyroid lobe volumes.

Entities:  

Mesh:

Year:  2003        PMID: 12573789     DOI: 10.1016/s0929-8266(02)00074-5

Source DB:  PubMed          Journal:  Eur J Ultrasound        ISSN: 0929-8266


  6 in total

1.  The estimation of the thyroid volume before surgery--an important prerequisite for minimally invasive thyroidectomy.

Authors:  M Ruggieri; A Fumarola; A Straniero; A Maiuolo; I Coletta; A Veltri; A Di Fiore; P Trimboli; P Gargiulo; M Genderini; M D'Armiento
Journal:  Langenbecks Arch Surg       Date:  2008-08-09       Impact factor: 3.445

2.  Analysis of tissue surrounding thyroid nodules by ultrasound digital images.

Authors:  Pierpaolo Trimboli; Fabiano Bini; Massimiliano Andrioli; Luca Giovanella; Maria Francesca Thorel; Luca Ceriani; Stefano Valabrega; Andrea Lenzi; Francesco Maria Drudi; Franco Marinozzi; Francesco Romanelli
Journal:  Endocrine       Date:  2014-07-06       Impact factor: 3.633

3.  Local reference ranges of thyroid volume in sudanese normal subjects using ultrasound.

Authors:  Mohamed Yousef; Abdelmoneim Sulieman; Bushra Ahmed; Alsafi Abdella; Khaled Eltom
Journal:  J Thyroid Res       Date:  2011-09-26

4.  A comparison of portable ultrasound and fully-equipped clinical ultrasound unit in the thyroid size measurement of the Indo-Pacific bottlenose dolphin.

Authors:  Brian C W Kot; Michael T C Ying; Fiona M Brook
Journal:  PLoS One       Date:  2012-01-17       Impact factor: 3.240

5.  The effect of preoperative Lugol's iodine on intraoperative bleeding in patients with hyperthyroidism.

Authors:  Yeliz Yilmaz; Kemal Erdinc Kamer; Orhan Ureyen; Erdem Sari; Turan Acar; Onder Karahalli
Journal:  Ann Med Surg (Lond)       Date:  2016-06-16

6.  Determination of thyroid volume in infants with suspected congenital hypothyroidism-the limitations of both subjective and objective evaluation.

Authors:  Chourouk Mansour; Yasmine Ouarezki; Jeremy Huw Jones; Morag Green; Emily Jane Stenhouse; Greg Irwin; Pia Hermanns; Joachim Pohlenz; Malcolm David Cairns Donaldson
Journal:  BJR Open       Date:  2020-06-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.