Physical and functional comparison of Coated VICRYL* Plus Antibacterial Suture (coated polyglactin 910 suture with triclosan) with Coated VICRYL* Suture (coated polyglactin 910 suture).

Mark Storch1, Howard Scalzo, Stephen Van Lue, Gabriel Jacinto.   

Abstract

BACKGROUND: The goal of this study was to compare the physical and functional properties of coated polyglactin 910 suture with and without triclosan by human assessment and instrument-based measurements.
METHODS: Surgeons specializing in general, orthopedic, plastic, or gynecologic surgery evaluated the suture materials in an in vivo porcine model with regard to (1) ease of passage through tissue, (2) first-throw knot holding, (3) knot tie-down smoothness, (4) knot security, (5) surgical handling, and (6) overall evaluation. Breaking strength retention was determined at 14, 21, 28, and 35 days post-implantation in rats using a tensile strength measurement device. The absorption rate was determined in rats by histopathology at 7, 28, 56, 63, 70, and 77 days post-implantation. The tactile smoothness and tie-down behavior of both wet and dry sutures were evaluated by product characterization technicians.
RESULTS: The scores for surgeons' evaluation of suture material were favorable and similar for both sutures. Surgeons could not reliably make a distinction in handling between the two sutures. Breaking strength retention was the same for both sutures, ranging from 79% on day 14 to 5% on day 35. Both sutures were essentially absorbed at 70 days post-implantation. Product characterization assessment of the two sutures found them to be indistinguishable.
CONCLUSION: The addition of triclosan to coated polyglactin 910 sutures did not affect physical handling properties or performance characteristics based on the testing and evaluations performed.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12573041     DOI: 10.1089/sur.2002.3.s1-65

Source DB:  PubMed          Journal:  Surg Infect (Larchmt)        ISSN: 1096-2964            Impact factor:   2.150


  4 in total

Review 1.  Meta-analysis of prevention of surgical site infections following incision closure with triclosan-coated sutures: robustness to new evidence.

Authors:  Frederic C Daoud; Charles E Edmiston; David Leaper
Journal:  Surg Infect (Larchmt)       Date:  2014-04-16       Impact factor: 2.150

2.  Biomechanical Outcomes of Bridge-enhanced Anterior Cruciate Ligament Repair Are Influenced by Sex in a Preclinical Model.

Authors:  Ata M Kiapour; Braden C Fleming; Martha M Murray
Journal:  Clin Orthop Relat Res       Date:  2015-08       Impact factor: 4.176

3.  Effects of suture choice on biomechanics and physeal status after bioenhanced anterior cruciate ligament repair in skeletally immature patients: a large-animal study.

Authors:  Patrick Vavken; Benedikt Proffen; Chris Peterson; Braden C Fleming; Jason T Machan; Martha M Murray
Journal:  Arthroscopy       Date:  2012-11-30       Impact factor: 4.772

Review 4.  Update on Suture Techniques in Corneal Transplantation: A Systematic Review.

Authors:  Luca Pagano; Haider Shah; Omar Al Ibrahim; Kunal A Gadhvi; Giulia Coco; Jason W Lee; Stephen B Kaye; Hannah J Levis; Kevin J Hamill; Francesco Semeraro; Vito Romano
Journal:  J Clin Med       Date:  2022-02-18       Impact factor: 4.241

  4 in total