Literature DB >> 12572804

A pulsed corona discharge switchable high resolution ion mobility spectrometer-mass spectrometer.

C A Hill1, C L P Thomas.   

Abstract

A pulsed corona discharge ionisation source, a candidate replacement for 63Ni ionisation sources for ion mobility spectrometry, is described along with a new design of ion mobility spectrometer-mass spectrometer. Preliminary research on the characterisation of the reactant ion peaks associated with the use of this ionisation source was undertaken by assembling a pulsed corona discharge ionisation switchable high-resolution ion mobility spectrometer-mass spectrometer to enable the mobility spectra, atmospheric chemical ionisation mass spectra and selected-mass mobility spectra to be obtained. With ammonia doping at 2.39 mg m(-3) in air and a water content of approximately 80 mg m(-3) in the positive mode the observed response was attributable to the formation of 1(H2O)(n)NH4]+ and [(H2O)n(NH3)NH4]+ in the reaction region. The observed responses in the negative mode were more complex with evidence for the formation [(H2O)(n)O2]-, [(H2O)(n)CO3]-, [(H2O)(n)HCO3]-, [(H2O)(n)CO4]- and [(H2O)(n)NO3]-. The responses due to these species were clearly discernible in the resultant mobility spectra, with enough oxygen-based species formed to support analytically useful responses.

Entities:  

Year:  2003        PMID: 12572804     DOI: 10.1039/b207558j

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  5 in total

1.  Alternately pulsed nanoelectrospray ionization/atmospheric pressure chemical ionization for ion/ion reactions in an electrodynamic ion trap.

Authors:  Xiaorong Liang; Yu Xia; Scott A McLuckey
Journal:  Anal Chem       Date:  2006-05-01       Impact factor: 6.986

2.  Collision-Induced Dissociation Study of the Adduct Ions Produced in NO3 (-)-Free Area of Atmospheric Pressure Negative Corona Discharges under Ambient Air Conditions.

Authors:  Kanako Sekimoto; Natsuki Matsuda; Mitsuo Takayama
Journal:  Mass Spectrom (Tokyo)       Date:  2013-05-03

3.  Specific interaction between negative atmospheric ions and organic compounds in atmospheric pressure corona discharge ionization mass spectrometry.

Authors:  Kanako Sekimoto; Mami Sakai; Mitsuo Takayama
Journal:  J Am Soc Mass Spectrom       Date:  2012-04-17       Impact factor: 3.109

4.  Determination of tobramycin in eye drops with an open-source hardware ion mobility spectrometer.

Authors:  Nattapong Chantipmanee; Peter C Hauser
Journal:  Anal Bioanal Chem       Date:  2022-04-05       Impact factor: 4.478

Review 5.  Negative Air Ions and Their Effects on Human Health and Air Quality Improvement.

Authors:  Shu-Ye Jiang; Ali Ma; Srinivasan Ramachandran
Journal:  Int J Mol Sci       Date:  2018-09-28       Impact factor: 5.923

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.