Literature DB >> 12571308

Total hip arthroplasty with use of the cementless Zweymüller Alloclassic system. A ten to thirteen-year follow-up study.

Eduardo Garcia-Cimbrelo1, Ana Cruz-Pardos, Rosario Madero, Miguel Ortega-Andreu.   

Abstract

BACKGROUND: The Zweymüller Alloclassic total hip arthroplasty system is widely used, although few intermediate-term studies have been published. The purpose of the present study was to evaluate the clinical and radiographic results of this system after ten years.
METHODS: One hundred and twenty-four consecutive primary total hip arthroplasties were performed with the Zweymüller Alloclassic cementless system at our institution between February 1988 and March 1991, and 104 hips (ninety-four patients) were retrospectively reviewed after a minimum duration of follow-up of ten years. The mean age of the patients at the time of the arthroplasty was 62.3 years (range, twenty-five to seventy-seven years). The mean duration of follow-up was 11.3 years. Standard radiographs were made for all patients immediately after the operation, at six and twelve months, and annually thereafter for at least ten years. Cox multivariate regression analysis was performed to assess the influence of various factors on survival of the implant.
RESULTS: The cumulative probability of not having a revision of any prosthetic component for any reason was 94.1% (95% confidence interval, 91.9% to 96.3%) at twelve years in the best-case scenario and 85.3% (95% confidence interval, 82.1% to 88.5%) at twelve years in the worst-case scenario for the entire series of 124 hips. Among the 104 hips in the follow-up study, three acetabular components and no stems were revised. Two hips had level-4 pain according to the system of Merle D'Aubigné and Postel. Seven acetabular components (7%) were loose at twelve years, and all stems had radiographic evidence of stable fixation. Acetabular cup loosening was related to a vertical cup angle (p = 0.0008, Student t test), acetabular wear of > or =1 mm (p = 0.001, Fisher exact test), and a 32-mm femoral head (p = 0.001, Fisher exact test). Although femoral osteolysis was seen in eighteen hips (17%) at twelve years, all osteolytic cavities were proximal and focal.
CONCLUSIONS: The Zweymüller Alloclassic prosthesis, particularly its femoral stem, demonstrated good results and durable fixation at a minimum of ten years of follow-up.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12571308     DOI: 10.2106/00004623-200302000-00017

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  22 in total

1.  Long-term follow-up of primary total hip arthroplasty with the Alloclassic Variall system.

Authors:  Josef Hochreiter; Giovanni Brusaferri; Klaus Kirschbichler; Katja Emmanuel
Journal:  Int Orthop       Date:  2015-08-18       Impact factor: 3.075

2.  Radiostereometric analysis: the hip.

Authors:  F Bottner; E Su; B Nestor; B Azzis; T P Sculco; M Bostrom
Journal:  HSS J       Date:  2005-09

3.  Partial weightbearing is not necessary after cementless total hip arthroplasty: a two-year prospective randomized study on 100 patients.

Authors:  Max Markmiller; Thomas Weiss; Peter Kreuz; Axel Rüter; Gerhard Konrad
Journal:  Int Orthop       Date:  2010-07-11       Impact factor: 3.075

4.  What works best, a cemented or cementless primary total hip arthroplasty?: minimum 17-year followup of a randomized controlled trial.

Authors:  Kristoff Corten; Robert B Bourne; Kory D Charron; Keegan Au; Cecil H Rorabeck
Journal:  Clin Orthop Relat Res       Date:  2010-07-13       Impact factor: 4.176

5.  Versatile application of short stem during total hip arthroplasty.

Authors:  Kwang-Jun Oh; Jae-Hyuk Yang
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-11-16

6.  Biomechanical comparison of two angular stable plate constructions for periprosthetic femur fracture fixation.

Authors:  Dirk Wähnert; Richard Schröder; Martin Schulze; Peter Westerhoff; Michael Raschke; Richard Stange
Journal:  Int Orthop       Date:  2013-10-11       Impact factor: 3.075

7.  Is the bone-bonding ability of a cementless total hip prosthesis enhanced by alkaline and heat treatments?

Authors:  Kazutaka So; Ayumi Kaneuji; Tadami Matsumoto; Shuichi Matsuda; Haruhiko Akiyama
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

8.  Ten to fifteen-year clinical and radiographic follow-up with a third-generation cementless stem in a young patient population.

Authors:  Peteris Studers; Danils Belajevs; Vitolds Jurkevics; Peteris Likums
Journal:  Int Orthop       Date:  2015-07-30       Impact factor: 3.075

9.  Factors influencing the revision rate of Zweymueller acetabular cup.

Authors:  H Effenberger; T Ramsauer; U Dorn; M Imhof
Journal:  Int Orthop       Date:  2004-03-31       Impact factor: 3.075

10.  [Results of cementless hip arthroplasty].

Authors:  A Grübl
Journal:  Radiologe       Date:  2006-09       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.