Literature DB >> 12571137

Breath-by-breath measurement of the volume displaced by diaphragm motion.

Bhajan Singh1, Janine A Panizza, Kevin E Finucane.   

Abstract

To develop an accurate method to measure the volume displaced by diaphragm motion (DeltaVdi) breath by breath, we compared DeltaVdi measured by a previously evaluated biplanar radiographic method (Singh B, Eastwood PR, and Finucane KE. J Appl Physiol 91: 1913-1923, 2001) at several lung volumes during vital capacity inspirations in 10 healthy and nine hyperinflated subjects with 1) DeltaVdi measured from the same chest X-rays by two previously described uniplanar methods (Petroll WM, Knight H, and Rochester DF. J Appl Physiol 69: 2175-2182, 1990; Verschakelen JA, Deschepper K, and Demendts M. J Appl Physiol 72: 1536-1540, 1992) and a proposed method that considered actual cross-sectional shape of the rib cage and spinal volume (DeltaVdi(S)); and 2) DeltaVdi(S) measured by lateral fluoroscopy in the same 10 healthy subjects. Relative to biplanar DeltaVdi, DeltaVdi(S) values from lateral chest X-rays and fluoroscopy were not different, whereas DeltaVdi values of Petroll et al. and Verschakelen et al. were increased by (means +/- SD) 1.98 +/- 1.59 and 1.16 +/- 0.82 liters, respectively (both P < 0.001). During quiet breathing, DeltaVdi(S) by lateral fluoroscopy was 66 +/- 16% of tidal volume and similar to that between functional residual capacity and one-half inspiratory capacity by the biplanar radiographic method. We conclude that accurate breath-by-breath measurements of DeltaVdi can be made by using lateral fluoroscopy.

Entities:  

Mesh:

Year:  2002        PMID: 12571137     DOI: 10.1152/japplphysiol.00256.2002

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  3 in total

1.  Computerized methods for determining respiratory phase on dynamic chest radiographs obtained by a dynamic flat-panel detector (FPD) system.

Authors:  Rie Tanaka; Shigeru Sanada; Takeshi Kobayashi; Masayuki Suzuki; Takeshi Matsui; Osamu Matsui
Journal:  J Digit Imaging       Date:  2006-03       Impact factor: 4.056

2.  Diaphragm curvature modulates the relationship between muscle shortening and volume displacement.

Authors:  Brad J Greybeck; Matthew Wettergreen; Rolf D Hubmayr; Aladin M Boriek
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2011-03-23       Impact factor: 3.619

3.  Functional and histopathological identification of the respiratory failure in a DMSXL transgenic mouse model of myotonic dystrophy.

Authors:  Petrica-Adrian Panaite; Thierry Kuntzer; Geneviève Gourdon; Johannes Alexander Lobrinus; Ibtissam Barakat-Walter
Journal:  Dis Model Mech       Date:  2012-11-23       Impact factor: 5.758

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.