The biomechanical effects of spondylolysis and its treatment.

Hisanori Mihara1, Katsuhiro Onari, Boyle C Cheng, Stephen M David, Thomas A Zdeblick.   

Abstract

STUDY
DESIGN: Biomechanical analysis of the level above pars defects was performed using calf lumbar spines.
OBJECTIVES: To evaluate whether complete spondylolysis contributes to the pathology of the upper adjacent motion segment to the pars defect. SUMMARY OF BACKGROUND DATA: It is well recognized that patients with spondylolysis show a higher incidence of spondylolisthesis or degenerative disc changes at the level of the pars defects. However, some authors have referred to the fact that disc damage may occur at the level above the defect and give rise to symptoms. However, no previous studies have been directed to the kinematic influence on the upper adjacent segment to pars defects.
METHODS: Nine fresh-frozen calf lumbar spines were used for this study. The bony defects were created on the L4 pars articularis bilaterally. Three linear extensometers and one specially designed angular extensometer were mounted across the L3-L4 and L4-L5 motion units. Nondestructive static loads, including axial compression, flexion-extension, and axial rotation, were applied on the specimens in four different conditions as follows: 1) intact spine; 2) bilateral pars defects on the L4 laminae; 3) pars defect repair with Buck technique; and 4) pedicle screw-rod fixation at L4-L5 after removal of the interarticular screws. Testing was performed on a material testing machine (MTS 858 Bionix test system, Minneapolis, MN), and load-displacement curves were recorded with the extensometers. Each test was performed for over five full sinusoidal loading cycles, and data from the fifth cycle were collected and analyzed.
RESULTS: After creating the pars interarticularis defects at L4, mobility at both the L3-L4 and L4-L5 motion units were increased in all loading conditions. The normalized range of motion (% ROM) as compared with the intact specimens showed that the pars defects increased the mobility at the upper adjacent level (L3-L4) to 106.4% in flexion-extension and to 120.1% in axial rotation; the differences were significant (P < 0.01). Consequently, the increased mobility was stabilized by applying Buck screws through the defects on both sides; however, the effect was not statistically significant. Furthermore, pedicle screw-rod fixation applied at the L4-L5 segment increased the intervertebral motion at the upper adjacent level, and % ROM in axial rotation was significantly increased to 119.2% of the intact spine (P < 0.05). Comparing the treatments' effects on the L3-L4 segment and that on L4-L5, the Buck screws restored the stability of both segments to the level of the intact spine, whereas the pedicle screw system limited the motion of L4-L5 motion and, on the contrary, increased the L3-L4 motion.
CONCLUSIONS: This biomechanical study exhibited that bilateral pars interarticularis defects increased the intervertebral mobility, not only at the involved level but also at the upper adjacent level to the lysis. The increased mobility at the upper segment was reduced by the Buck screw technique. However, this was increased again by the pedicle screw system applied on the involved segment. If clinically applicable, fixation of the pars defect alone appears to cause less adjacent level mechanical stress than pedicle screw-rod motion segment fixation.

Entities:  

Mesh:

Year:  2003        PMID: 12567023     DOI: 10.1097/01.BRS.0000042226.59713.0E

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  16 in total

Review 1.  A proposal for a surgical classification of pediatric lumbosacral spondylolisthesis based on current literature.

Authors:  Jean-Marc Mac-Thiong; Hubert Labelle
Journal:  Eur Spine J       Date:  2006-06-07       Impact factor: 3.134

2.  Three dimensional finite element analysis of the pediatric lumbar spine. Part II: biomechanical change as the initiating factor for pediatric isthmic spondylolisthesis at the growth plate.

Authors:  Koichi Sairyo; Vijay K Goel; Akiyoshi Masuda; Srilakshmi Vishnubhotla; Ahmad Faizan; Ashok Biyani; Nabil Ebraheim; Daisuke Yonekura; Ri-Ichi Murakami; Tomoya Terai
Journal:  Eur Spine J       Date:  2006-04-14       Impact factor: 3.134

Review 3.  Spondylolytic spondylolisthesis: various imaging features and natural courses.

Authors:  Tetsuo Nakayama; Shigeru Ehara
Journal:  Jpn J Radiol       Date:  2014-11-23       Impact factor: 2.374

Review 4.  Lumbar spondylolysis: a review.

Authors:  Antonio Leone; Alessandro Cianfoni; Alfonso Cerase; Nicola Magarelli; Lorenzo Bonomo
Journal:  Skeletal Radiol       Date:  2010-05-04       Impact factor: 2.199

5.  Direct pars repair surgery using two different surgical methods : pedicle screw with universal hook system and direct pars screw fixation in symptomatic lumbar spondylosis patients.

Authors:  Myung-Hoon Shin; Kyeong-Sik Ryu; Nitesh Kumar Rathi; Chun-Kun Park
Journal:  J Korean Neurosurg Soc       Date:  2012-01-31

Review 6.  Back pain in adolescent athletes: a narrative review.

Authors:  Neeraj Vij; Ian Naron; Hannah Tolson; Arthur Rezayev; Alan D Kaye; Omar Viswanath; Ivan Urits
Journal:  Orthop Rev (Pavia)       Date:  2022-08-05

Review 7.  Lumbar spondylolysis - Current concepts review.

Authors:  Ujjwal K Debnath
Journal:  J Clin Orthop Trauma       Date:  2021-07-30

8.  Direct repair of defects in lumbar spondylolysis with a new pedicle screw hook fixation: clinical, functional and Ct-assessed study.

Authors:  Felix Debusscher; Serge Troussel
Journal:  Eur Spine J       Date:  2007-05-23       Impact factor: 3.134

9.  Direct repair of lumbar spondylolysis by Buck's technique.

Authors:  S Rajasekaran; M Subbiah; Ajoy Prasad Shetty
Journal:  Indian J Orthop       Date:  2011-03       Impact factor: 1.251

10.  A universal pedicle screw and V-rod system for lumbar isthmic spondylolysis: a retrospective analysis of 21 cases.

Authors:  Xiong-sheng Chen; Sheng-yuan Zhou; Lian-shun Jia; Xiao-min Gu; Lei Fang; Wei Zhu
Journal:  PLoS One       Date:  2013-05-17       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.