Literature DB >> 12564515

Analysis of programming maps and its application for balancing multichannel cochlear implants.

Manuel Sainz1, Angel de la Torre, Cristina Roldán, Jose M Ruiz, José L Vargas.   

Abstract

Channel balancing is important for correct perception when using multichannel cochlear implants. In this paper we analyse the effect of channel imbalance on hearing perception in cochlear-implanted patients. Based on warble tone audiometry measured for 10 implanted patients, we evaluate how hearing sensitivity is affected by an imbalance. We also study the distribution along the cochlea of the programming parameters for 146 patients. The parameters are compared for different groups of patients (defined taking into account the age at implantation, the stimulation mode, and the presence of severe cochlear damage). The aim of this study is to obtain information that can be useful for balancing the channels for the patients in the different groups, as well as to evaluate the effect of an imbalance on perception. These results provide some complementary information that can be applied to the correct fitting of the cochlear implant processor.

Entities:  

Mesh:

Year:  2003        PMID: 12564515     DOI: 10.3109/14992020309056084

Source DB:  PubMed          Journal:  Int J Audiol        ISSN: 1499-2027            Impact factor:   2.117


  5 in total

1.  Programming characteristics of cochlear implants in children: effects of aetiology and age at implantation.

Authors:  Paola V Incerti; Teresa Y C Ching; Sanna Hou; Patricia Van Buynder; Christopher Flynn; Robert Cowan
Journal:  Int J Audiol       Date:  2017-09-08       Impact factor: 2.117

Review 2.  Cochlear Implantation for Children and Adults with Severe-to-Profound Hearing Loss.

Authors:  Lavin K Entwisle; Sarah E Warren; Jessica J Messersmith
Journal:  Semin Hear       Date:  2018-10-26

3.  Setting and reaching targets with computer-assisted cochlear implant fitting.

Authors:  Bart Vaerenberg; Geert De Ceulaer; Zoltán Szlávik; Patrizia Mancini; Andreas Buechner; Paul J Govaerts
Journal:  ScientificWorldJournal       Date:  2014-03-16

4.  ARTFit-A Quick and Reliable Tool for Performing Initial Fittings in Users of MED-EL Cochlear Implants.

Authors:  Lutz Gärtner; Timo Bräcker; Mathias Kals; Richard T Penninger; Mareike Billinger-Finke; Thomas Lenarz; Andreas Büchner
Journal:  Life (Basel)       Date:  2022-02-11

5.  Optimized SNR-based ECAP threshold determination is comparable to the judgement of human evaluators.

Authors:  Lutz Gärtner; Philipp Spitzer; Kathrin Lauss; Marko Takanen; Thomas Lenarz; Sebastian Hoth
Journal:  PLoS One       Date:  2021-11-01       Impact factor: 3.240

  5 in total