Literature DB >> 12561097

Paravalvular leakage causing hemolytic anemia at 8-9 years after mitral valve replacement.

Yoshio Misawa1, Hiroaki Konishi, Tsutomu Saito, Katsuo Fuse.   

Abstract

We report two similar cases of women, aged 52 and 71 years, who developed shortness of breath or easy fatigability at 8-9 years after mitral valve replacement of the mitral valve in each patient, the echocardiographic study revealed paravalvular leakage. Previous examination before the appearance of symptoms had revealed a well-functioned prosthetic valve, and no hematological abnormality had been detected. The hemoglobin levels at admission were 6.4 and 6.6 g/dl, and their serum lactate dehydrogenase levels were 5218 and 4608 mU/ml. Each successfully underwent another valve replacement, and after surgery, the hemolytic anemia and the symptoms disappeared.

Entities:  

Mesh:

Year:  2002        PMID: 12561097     DOI: 10.1007/BF02913169

Source DB:  PubMed          Journal:  Jpn J Thorac Cardiovasc Surg        ISSN: 1344-4964


  7 in total

1.  Hemolysis after mitral valve replacement with mechanical valve prostheses.

Authors:  M Ninomiya; K Yagyu; Y Kaneko; Y Kotsuka; S Takamoto
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2001-04

2.  Reoperation for hemolytic, anaemia complicating mitral valve repair.

Authors:  R J Cerfolio; T A Orszulak; R C Daly; H V Schaff
Journal:  Eur J Cardiothorac Surg       Date:  1997-03       Impact factor: 4.191

3.  Fourteen year experience with the omnicarbon prosthetic heart valve.

Authors:  Y Misawa; K Fuse; T Saito; H Konishi; S I Oki
Journal:  ASAIO J       Date:  2001 Nov-Dec       Impact factor: 2.872

4.  Standard aortic St. Jude valve at 18 years: performance profile and determinants of outcome.

Authors:  O Lund; S L Nielsen; H Arildsen; L B Ilkjaer; H K Pilegaard
Journal:  Ann Thorac Surg       Date:  2000-05       Impact factor: 4.330

Review 5.  Red cell membrane damage.

Authors:  F A Kuypers
Journal:  J Heart Valve Dis       Date:  1998-07

6.  [Ten years experience with the St. Jude Medical valve prosthesis for mitral valve replacement].

Authors:  S Aoyagi; K Tanaka; Y Nishi; M Yamashita; A Oryoji; H Hara; K Kosuga; K Oishi
Journal:  Nihon Kyobu Geka Gakkai Zasshi       Date:  1991-08

7.  Clinical experience with the Omnicarbon prosthetic heart valve.

Authors:  Y Misawa; T Hasegawa; M Kato
Journal:  J Thorac Cardiovasc Surg       Date:  1993-01       Impact factor: 5.209

  7 in total
  2 in total

1.  Clinical features of third open-heart valve surgery at the same valve position.

Authors:  Shin-ichi Ohki; Yoshio Misawa; Tsutomu Saito; Hiroaki Konishi; Yuichiro Kaminishi; Yasuhito Sakano; Kei Aizawa; Hideki Takahashi; Masanobu Taguchi; Takako Shinohara
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2005-12

2.  Pathogenesis of paravalvular leakage as a complication occurring in the late phase after surgery.

Authors:  Fumiaki Kuwabara; Akihiko Usui; Yoshimori Araki; Yuji Narita; Shinichi Mizutani; Hideki Oshima; Yuichi Ueda
Journal:  J Artif Organs       Date:  2011-04-20       Impact factor: 1.731

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.