Literature DB >> 12559826

Multiple surface properties of worn RGP lenses and adhesion of Pseudomonas aeruginosa.

G M Bruinsma1, M Rustema-Abbing, J de Vries, H J Busscher, M L van der Linden, J M M Hooymans, H C van der Mei.   

Abstract

The aim of this study is to determine rigid gas permeable (RGP) lens surface properties prior to and after wear that are influential on adhesion of Pseudomonas aeruginosa. After 10 and 50 days of wear and after end-stage use, lenses were collected for determination of physico-chemical surface properties and bacterial adhesion in a parallel plate flow chamber. Water contact angles on unused RGP lenses amounted 47+/-13 degrees and were affected by wear. In addition, %O at the lens surfaces, as determined by X-ray photoelectron spectroscopy increased after use for 10 and 50 days, but decreased after end-stage wear. The %N hardly increased after wear and, in line, SDS-PAGE did not indicate adsorbed proteins. The surface roughness of the lenses, as measured by atomic force microscopy amounted 9 nm after 10 and 50 days of use, but end-stage lenses were significantly rougher (48+/-23 nm). Moreover, initial deposition of P. aeruginosa #3 increased with increasing roughness for end-stage lenses. Multiple regression analysis, however, revealed that both physical and chemical surface properties were predictive for initial bacterial deposition to lens surfaces. After 10 days of wear, bacterial deposition was governed by the water contact angle, surface roughness, %O, %N, and %Si, while after 50 days of wear the surface roughness, %N, and %Si were found predictive for bacterial deposition. Initial bacterial deposition to end-stage lenses was solely dependent on the surface roughness. Summarizing, physico-chemical surface properties of RGP lenses change slightly during the first 10-50 days of wear, but end-stage lenses all had increased surface roughness, concurrent with increased bacterial adhesion.

Entities:  

Mesh:

Year:  2003        PMID: 12559826     DOI: 10.1016/s0142-9612(02)00542-2

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  3 in total

1.  Atomic force microscopy and scanning electron microscopy analysis of daily disposable limbal ring contact lenses.

Authors:  Kathrine Osborn Lorenz; Joseph Kakkassery; Danielle Boree; David Pinto
Journal:  Clin Exp Optom       Date:  2014-04-02       Impact factor: 2.742

2.  Influence of Contact Lens Materials and Cleaning Procedures on Bacterial Adhesion and Biofilm Formation.

Authors:  Auemphon Mordmuang; Lunla Udomwech; Kulwadee Karnjana
Journal:  Clin Ophthalmol       Date:  2021-06-08

3.  Comparison of Antibacterial Adhesion When Salivary Pellicle Is Coated on Both Poly(2-hydroxyethyl-methacrylate)- and Polyethylene-glycol-methacrylate-grafted Poly(methyl methacrylate).

Authors:  Bor-Shiunn Lee; Yu-Jia Chen; Ta-Chin Wei; Tien-Li Ma; Che-Chen Chang
Journal:  Int J Mol Sci       Date:  2018-09-14       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.