Literature DB >> 12558687

A comparison of image restoration approaches applied to three-dimensional confocal and wide-field fluorescence microscopy.

P. J Verveer1, M. J Gemkow, T. M Jovin.   

Abstract

We have compared different image restoration approaches for fluorescence microscopy. The most widely used algorithms were classified with a Bayesian theory according to the assumed noise model and the type of regularization imposed. We considered both Gaussian and Poisson models for the noise in combination with Tikhonov regularization, entropy regularization, Good's roughness and without regularization (maximum likelihood estimation). Simulations of fluorescence confocal imaging were used to examine the different noise models and regularization approaches using the mean squared error criterion. The assumption of a Gaussian noise model yielded only slightly higher errors than the Poisson model. Good's roughness was the best choice for the regularization. Furthermore, we compared simulated confocal and wide-field data. In general, restored confocal data are superior to restored wide-field data, but given sufficient higher signal level for the wide-field data the restoration result may rival confocal data in quality. Finally, a visual comparison of experimental confocal and wide-field data is presented.

Year:  1999        PMID: 12558687     DOI: 10.1046/j.1365-2818.1999.00421.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  14 in total

1.  Scanning holographic microscopy of three-dimensional fluorescent specimens.

Authors:  Guy Indebetouw; Wenwei Zhong
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2006-07       Impact factor: 2.129

2.  Three-dimensional FRET reconstruction microscopy for analysis of dynamic molecular interactions in live cells.

Authors:  Adam D Hoppe; Spencer L Shorte; Joel A Swanson; Rainer Heintzmann
Journal:  Biophys J       Date:  2008-03-13       Impact factor: 4.033

3.  Theoretical limits on errors and acquisition rates in localizing switchable fluorophores.

Authors:  Alexander R Small
Journal:  Biophys J       Date:  2009-01       Impact factor: 4.033

4.  Plasma membrane sterol distribution resembles the surface topography of living cells.

Authors:  Daniel Wüstner
Journal:  Mol Biol Cell       Date:  2006-10-25       Impact factor: 4.138

5.  A motion correction framework for time series sequences in microscopy images.

Authors:  Ankur N Kumar; Kurt W Short; David W Piston
Journal:  Microsc Microanal       Date:  2013-02-15       Impact factor: 4.127

6.  Model Convolution: A Computational Approach to Digital Image Interpretation.

Authors:  Melissa K Gardner; Brian L Sprague; Chad G Pearson; Benjamin D Cosgrove; Andrew D Bicek; Kerry Bloom; E D Salmon; David J Odde
Journal:  Cell Mol Bioeng       Date:  2010-02-06       Impact factor: 2.321

7.  Fluorescence microscopy datasets for training deep neural networks.

Authors:  Guy M Hagen; Justin Bendesky; Rosa Machado; Tram-Anh Nguyen; Tanmay Kumar; Jonathan Ventura
Journal:  Gigascience       Date:  2021-05-05       Impact factor: 6.524

8.  An open-source deconvolution software package for 3-D quantitative fluorescence microscopy imaging.

Authors:  Y Sun; P Davis; E A Kosmacek; F Ianzini; M A Mackey
Journal:  J Microsc       Date:  2009-12       Impact factor: 1.758

9.  Fluorescence recovery after photobleaching and photoconversion in multiple arbitrary regions of interest using a programmable array microscope.

Authors:  Guy M Hagen; Wouter Caarls; Keith A Lidke; Anthony H B De Vries; Cornelia Fritsch; B George Barisas; Donna J Arndt-Jovin; Thomas M Jovin
Journal:  Microsc Res Tech       Date:  2009-06       Impact factor: 2.769

10.  Three-Dimensional Reconstruction of Three-Way FRET Microscopy Improves Imaging of Multiple Protein-Protein Interactions.

Authors:  Brandon L Scott; Adam D Hoppe
Journal:  PLoS One       Date:  2016-03-29       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.