Literature DB >> 12554151

Determination of Simvastatin in human plasma by liquid chromatography-mass spectrometry.

Haitao Yang1, Yan Feng, Yiwen Luan.   

Abstract

A simple, sensitive and selective liquid chromatography coupled with electrospray ionization mass spectrometry (LC/ESI/MS) method for the determination of simvastatin (I) has been developed. After extraction by ethyl acetate, using lovastatin (II) as internal standard, solutes are separated on a C(18) column with a mobile phase consisting of methanol-water (9:1). Detection is performed on an atmospheric pressure ionization single quadruple mass spectrometer equipped with an ESI interface and operates in positive ionization mode. Simvastatin quantification was realized by computing peak area ratio (I/II) of the extracts analyzed in SIM mode (m/z: 441 and m/z: 427 for I and II, respectively) and comparing them with calibration curve (r=0.9997). Accuracy and precision for the assay were determined by calculating the intra-batch and inter-batch variation at three concentrations 0.1, 5.0, 10.0 ng/ml; the intra batch relative standard deviation (RSD) was less than 10% and ranged from 1.8 to 8.5%, respectively; the inter-batch RSD was less than 20% and ranged from 4.1 to 16.5%. The limit of detection was 0.05 ng/ml. Copyright 2002 Elsevier Science B.V.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12554151     DOI: 10.1016/s1570-0232(02)00800-0

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  11 in total

1.  Decreased exposure of simvastatin and simvastatin acid in a rat model of type 2 diabetes.

Authors:  Dan Xu; Feng Li; Mian Zhang; Ji Zhang; Can Liu; Meng-yue Hu; Ze-yu Zhong; Ling-ling Jia; Da-wei Wang; Jie Wu; Li Liu; Xiao-dong Liu
Journal:  Acta Pharmacol Sin       Date:  2014-08-25       Impact factor: 6.150

2.  Simvastatin decreases IL-6 and IL-8 production in epithelial cells.

Authors:  K Sakoda; M Yamamoto; Y Negishi; J K Liao; K Node; Y Izumi
Journal:  J Dent Res       Date:  2006-06       Impact factor: 6.116

3.  Statins influence epithelial expression of the anti-microbial peptide LL-37/hCAP-18 independently of the mevalonate pathway.

Authors:  P Lüthje; S Walker; W Kamolvit; S Mohanty; K Pütsep; A Brauner
Journal:  Clin Exp Immunol       Date:  2018-10-11       Impact factor: 4.330

4.  Effect of simvastatin on the osteogenetic behavior of alveolar osteoblasts and periodontal ligament cells.

Authors:  Shutai Liu; Kristina Bertl; Hongchen Sun; Zhong-Hao Liu; Oleh Andrukhov; Xiaohui Rausch-Fan
Journal:  Hum Cell       Date:  2012-03-08       Impact factor: 4.174

5.  Liquid chromatography-tandem mass spectrometry assay for the simultaneous quantification of simvastatin, lovastatin, atorvastatin, and their major metabolites in human plasma.

Authors:  Jiang Wang; Jasmine A Luzum; Mitch A Phelps; Joseph P Kitzmiller
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2015-01-13       Impact factor: 3.205

6.  Method Validation for Analysis of Simvastatin in Human Plasma Using Liquid Chromatography Tandem Mass Spectrometry (LC-MS-MS).

Authors:  Khaled M Alakhali
Journal:  J Clin Diagn Res       Date:  2013-12-15

7.  Effect of hyperlipidemia on response to nonsurgical periodontal therapy: Statin users versus nonusers.

Authors:  Aditi Sangwan; Shikha Tewari; Harpreet Singh; Rajinder Kumar Sharma; Satish Chander Narula
Journal:  Eur J Dent       Date:  2016 Jan-Mar

8.  Comparison of conventional and supported liquid extraction methods for the determination of sitagliptin and simvastatin in rat plasma by LC-ESI-MS/MS.

Authors:  B Ramesh; N Manjula; S R Bijargi; V U M Sarma; P Sita Devi
Journal:  J Pharm Anal       Date:  2014-12-02

9.  Validated LC-MS/MS method for simultaneous determination of SIM and its acid form in human plasma and cell lysate: Pharmacokinetic application.

Authors:  Tamer A Ahmed; Jamie Horn; John Hayslip; Markos Leggas
Journal:  J Pharm Anal       Date:  2012-08-07

10.  Preparation and Characterization of Carbon Paste Electrode Bulk-Modified with Multiwalled Carbon Nanotubes and Its Application in a Sensitive Assay of Antihyperlipidemic Simvastatin in Biological Samples.

Authors:  Amir M Ashrafi; Lukáš Richtera
Journal:  Molecules       Date:  2019-06-13       Impact factor: 4.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.