Estimation of myocardial blood flow and myocardial flow reserve by 99mTc-sestamibi imaging: comparison with the results of [15O]H2O PET.

Yoshinori Ito1, Chietsugu Katoh, Kazuyuki Noriyasu, Yuji Kuge, Hideto Furuyama, Koichi Morita, Tetsuro Kohya, Akira Kitabatake, Nagara Tamaki.   

Abstract

We developed a noninvasive method to quantitatively estimate the myocardial blood flow (MBF) index and flow reserve (MFR) using dynamic and static data obtained with technetium-99m sestamibi, and compared the results with MBF and MFR measured by oxygen-15-labeled water ([(15)O]H(2)O) PET. Twenty patients with coronary artery disease (CAD) and nine normal subjects underwent both (99m)Tc-sestamibi and PET studies within 2 weeks. From the anterior view, dynamic data were acquired for 2 min immediately after the injection of (99m)Tc-sestamibi, and planar static images were also obtained after 5 min at rest and during ATP stress (0.16 mg kg(-1) min(-1) for 5 min) on another day. The area under the time-activity curve on the aortic arch (Aorta ACU), myocardial weight with the SPET image (M), and the myocardial count on the planar image for 1 min (C(m)) were obtained. The MBF index (MBFI) was calculated as follows: MBFI=Cm/Aorta ACU x 100M. MFR was measured by dividing the MBFI at ATP stress by MBFI at rest. The MBFI measured by (99m)Tc-sestamibi was significantly correlated with MBF obtained using [(15)O]H(2)O PET (MBFI=13.174+11.732 x MBF, r=0.821, P<0.001). Furthermore, MFR measured by (99m)Tc-sestamibi was well correlated with that obtained using [(15)O]H(2)O PET, with some underestimation (r=0.845, P<0.001). MFR using (99m)Tc-sestamibi in patients with CAD was significantly lower than that in normal subjects (CAD: 1.484+/-0.256 vs normal: 2.127+/-0.308, P<0.001). These data suggest that the MBFI and MFR can be measured with (99m)Tc-sestamibi. This may be useful for the quantitative assessment of CAD, especially in those patients with diffuse coronary disease.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12552347     DOI: 10.1007/s00259-002-1031-y

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  24 in total

1.  Reduced coronary flow reserve in patients with primary hyperparathyroidism: a study by G-SPECT myocardial perfusion imaging.

Authors:  Cecilia Marini; Massimo Giusti; Riccardo Armonino; Giorgio Ghigliotti; GianPaolo Bezante; Lara Vera; Silvia Morbelli; Elena Pomposelli; Michela Massollo; Patrizia Gandolfo; Francesco Minuto; Gianmario Sambuceti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-09-04       Impact factor: 9.236

2.  The clinical assessment of coronary flow reserve in patients with coronary artery disease.

Authors:  Michael Ragosta
Journal:  J Nucl Cardiol       Date:  2004 Nov-Dec       Impact factor: 5.952

Review 3.  Methodology for quantifying absolute myocardial perfusion with PET and SPECT.

Authors:  Martin A Lodge; Frank M Bengel
Journal:  Curr Cardiol Rep       Date:  2007-04       Impact factor: 2.931

4.  Challenges for measurement of myocardial perfusion and perfusion reserve by SPECT imaging.

Authors:  Richard C Brunken
Journal:  J Nucl Cardiol       Date:  2007-04       Impact factor: 5.952

5.  Assessment of coronary flow reserve by sestamibi imaging in patients with typical chest pain and normal coronary arteries.

Authors:  Giovanni Storto; Anna Rita Sorrentino; Teresa Pellegrino; Raffaele Liuzzi; Mario Petretta; Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-01-06       Impact factor: 9.236

6.  Quantitative myocardial perfusion from static cardiac and dynamic arterial CT.

Authors:  Michael Bindschadler; Kelley R Branch; Adam M Alessio
Journal:  Phys Med Biol       Date:  2018-05-21       Impact factor: 3.609

Review 7.  Present and future of clinical cardiovascular PET imaging in Europe--a position statement by the European Council of Nuclear Cardiology (ECNC).

Authors:  D Le Guludec; R Lautamäki; J Knuuti; J J Bax; F M Bengel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-06-26       Impact factor: 9.236

8.  Assessment of the arterial input function for estimation of coronary flow reserve by single photon emission computed tomography: comparison of two different approaches.

Authors:  Giovanni Storto; Andrea Soricelli; Teresa Pellegrino; Mario Petretta; Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12       Impact factor: 9.236

9.  Incremental prognostic value of coronary flow reserve assessed with single-photon emission computed tomography.

Authors:  Stefania Daniele; Carmela Nappi; Wanda Acampa; Giovanni Storto; Teresa Pellegrino; Francesca Ricci; Evgjeni Xhoxhi; Francesco Porcaro; Mario Petretta; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2011-05-28       Impact factor: 5.952

10.  Optimization of flow reserve measurement using SPECT technology to evaluate the determinants of coronary microvascular dysfunction in diabetes.

Authors:  Cecilia Marini; GianPaolo Bezante; Patrizia Gandolfo; Elisa Modonesi; Silvia D Morbelli; Angelo Depascale; Daniela Rollando; Davide Maggi; Manuela Albertelli; Riccardo Armonino; Manrico Balbi; Claudio Brunelli; Renzo Cordera; Gianmario Sambuceti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12-03       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.