Comparison of two cyclosporine formulations in healthy Middle Eastern volunteers: bioequivalence of the new Sigmasporin Microoral and Sandimmun Neoral.

Naji M Najib1, Nasir Idkaidek, Ayman Adel, B Mohammed, Sahar Al-Masri, Isra' Admour, S Mahmood Alam, Ruwayda Dham.   

Abstract

A study was conducted to establish bioequivalence between two oral cyclosporine 100 mg capsules, Sigmasporin Microoral (Gulf Pharmaceutical Industries - Julphar, United Arab Emirates, under technical co-operation with Sigma Pharma, Brazil) and Sandimmun Neoral (Novartis, Switzerland), in a Middle Eastern population, even though both formulations were found to be bioequivalent earlier in a Brazilian population (data on file). It was designed as a randomized, open label, two-way crossover study in which 30 fasting, healthy male volunteers received a single 100 mg cyclosporine dose with 240 ml of water on two treatment days separated by a 1 week washout period. After dosing, serial blood samples were collected for a period of 24 h. Plasma was analyzed for cyclosporine A by a sensitive, reproducible and accurate HPLC method with MS detection capable of detecting cyclosporine A in the range of 5-400 ng/ml with a limit of quantitation of 5 ng/ml. Various pharmacokinetic parameters including AUC(0-t), AUC(0- proportional, variant ), C(max), T(max), T(1/2), and lambda(Z) were determined from plasma concentrations of both formulations. AUC(0-t), AUC(0- proportional, variant ), and C(max) were tested for bioequivalence after log-transformation of data. No significant difference was found based on ANOVA; 90% confidence intervals (82.98-110.57% for AUC(0-t), 81.57-124.71% for AUC(0- proportional, variant ), 80.15-98.91% for C(max)) for these parameters were found to be within the bioequivalence acceptance range of 80-125%. Based on these statistical inferences, it was concluded that Sigmasporin Microoral is bioequivalent to Sandimmun Neoral.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12551705     DOI: 10.1016/s0939-6411(02)00157-1

Source DB:  PubMed          Journal:  Eur J Pharm Biopharm        ISSN: 0939-6411            Impact factor:   5.571


  2 in total

1.  Development and validation of a HPLC method for the determination of cyclosporine a in new bioadhesive nanoparticles for oral administration.

Authors:  M Pecchio; H Salman; J M Irache; M J Renedo; M C Dios-Viéitez
Journal:  Indian J Pharm Sci       Date:  2014-03       Impact factor: 0.975

Review 2.  Bioavailability, Efficacy and Safety of Generic Immunosuppressive Drugs for Kidney Transplantation: A Systematic Review and Meta-Analysis.

Authors:  Evangelos Tsipotis; Navin R Gupta; Gowri Raman; Elias Zintzaras; Bertrand L Jaber
Journal:  Am J Nephrol       Date:  2016-08-31       Impact factor: 4.605

  2 in total