Literature DB >> 12545007

Adrenal insufficiency during septic shock.

Paul E Marik1, Gary P Zaloga.   

Abstract

OBJECTIVE: To determine whether a baseline (random) cortisol concentration <25 microg/dL in patients with septic shock was a better discriminator of adrenal insufficiency than the standard (250 microg) and the low-dose (1 microg) corticotropin stimulation tests as assessed by the hemodynamic response to steroid replacement.
SETTING: Intensive care unit. PATIENTS: Fifty-nine patients with septic shock. Their mean age was 57 +/- 16.7 yrs; 29 were male.
INTERVENTIONS: A baseline cortisol concentration was obtained. Patients then received an intravenous injection of 1 microg of corticotropin (low-dose test) followed 60 mins later by an injection of 249 microg of corticotropin (high-dose test). Cortisol concentrations were obtained 30 and 60 mins after low- and high-dose corticotropin. All patients were administered hydrocortisone (100 mg every 8 hrs) for the first 24 hrs while awaiting results of cortisol assessment. Patients were considered steroid responsive if the pressor agent could be discontinued within 24 hrs of the first dose of hydrocortisone.
MEASUREMENTS AND MAIN RESULTS: Forty-seven percent of patients died. Twenty-two percent of patients met the diagnostic criteria of adrenal insufficiency by the low-dose test and 8% by the high-dose test. However, 61% of patients met the criteria of adrenal insufficiency when we used a baseline cortisol concentration of <25 microg/dL. Twenty-two patients (37%) were steroid responsive; the baseline serum cortisol was 14.1 +/- 5.2 microg/dL in the steroid-responsive patients compared with 33.3 +/- 18 microg/dL in the steroid-nonresponsive patients (p <.0001). Ninety-five percent of steroid-responsive patients had a baseline cortisol concentration <25 microg/dL. Fifty-four percent of steroid responders had a diagnostic low-dose test and 22% a diagnostic high-dose test. Receiver operating characteristic curve analysis revealed that a stress cortisol concentration of 23.7 microg/dL was the most accurate diagnostic threshold for determination of the hemodynamic response to glucocorticoid therapy.
CONCLUSIONS: Adrenal insufficiency is common in patients with septic shock, the incidence depending largely on the diagnostic test and criteria used to make the diagnosis. There is clearly no absolute serum cortisol concentration that distinguishes an adequate from an insufficient adrenal response. However, we believe that a random cortisol concentration of <25 microg/dL in a highly stressed patient is a useful diagnostic threshold for the diagnosis of adrenal insufficiency.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12545007     DOI: 10.1097/00003246-200301000-00022

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  65 in total

1.  Adrenal gland volume measurement in septic shock and control patients: a pilot study.

Authors:  Stephanie Nougaret; B Jung; S Aufort; G Chanques; S Jaber; B Gallix
Journal:  Eur Radiol       Date:  2010-06-04       Impact factor: 5.315

2.  Initial observations regarding free cortisol quantification logistics among critically ill children.

Authors:  Jerry J Zimmerman; Ruth M Barker; Rhona Jack
Journal:  Intensive Care Med       Date:  2010-08-19       Impact factor: 17.440

3.  Cortisol changes among patients with septic shock and the relationship to ICU and hospital stay.

Authors:  Sergei Goodman; Charles L Sprung; Daniel Ziegler; Yoram G Weiss
Journal:  Intensive Care Med       Date:  2005-09-07       Impact factor: 17.440

Review 4.  [New approaches to intensive care for sepsis].

Authors:  G Marx; T Schuerholz; K Reinhart
Journal:  Chirurg       Date:  2005-09       Impact factor: 0.955

5.  Adrenal axis function does not appear to be associated with hemodynamic improvement in septic shock patients systematically receiving glucocorticoid therapy.

Authors:  Jerome Morel; Christophe Venet; Yannis Donati; David Charier; Jerome Liotier; Delphine Frere-Meunier; Stephane Guyomarc'h; Eric Diconne; Jean Claude Bertrand; Bertrand Souweine; Laurent Papazian; Fabrice Zeni
Journal:  Intensive Care Med       Date:  2006-06-20       Impact factor: 17.440

6.  The hollow adrenal gland sign: a newly described enhancing pattern of the adrenal gland on dual-phase contrast-enhanced CT for predicting the prognosis of patients with septic shock.

Authors:  Yang Peng; Qiuxia Xie; Huanjun Wang; Zhi Lin; Fan Zhang; Xuhui Zhou; Jian Guan
Journal:  Eur Radiol       Date:  2019-04-01       Impact factor: 5.315

7.  Adrenal-exhaustion syndrome in patients with liver disease.

Authors:  Paul E Marik
Journal:  Intensive Care Med       Date:  2006-01-24       Impact factor: 17.440

Review 8.  Sepsis: a clinical update.

Authors:  Corey E Ventetuolo; Mitchell M Levy
Journal:  Clin J Am Soc Nephrol       Date:  2007-11-07       Impact factor: 8.237

Review 9.  Update on adrenal insufficiency in patients with liver cirrhosis.

Authors:  Anca Trifan; Stefan Chiriac; Carol Stanciu
Journal:  World J Gastroenterol       Date:  2013-01-28       Impact factor: 5.742

10.  Successful treatment with hydrocortisone for heat stroke with critical illness-related corticosteroid insufficiency: transitional changes in serum cytokine and cortisol concentrations.

Authors:  Takashi Miyauchi; Ryosuke Tsuruta; Satoshi Kutsuna; Takashi Nakahara; Motoki Fujita; Shunji Kasaoka; Tsuyoshi Maekawa
Journal:  J Anesth       Date:  2009-05-15       Impact factor: 2.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.