Literature DB >> 12545000

Overestimation of pulmonary artery occlusion pressure in pulmonary hypertension due to partial occlusion.

James W Leatherman1, Robert S Shapiro.   

Abstract

OBJECTIVE: To evaluate partial occlusion in patients with pulmonary hypertension with regard to a) the degree to which it leads to overestimation of pulmonary artery occlusion pressure (Ppao) and b) identification of factors that could enhance its recognition.
DESIGN: Observational descriptive study.
SETTING: Medical intensive care unit. PATIENTS: Fourteen patients with pulmonary hypertension and an increased pulmonary artery diastolic pressure (Ppad) - Ppao gradient (> or = 10 mm Hg).
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: The Ppao was recorded during partial occlusion (partial Ppao) and after catheter repositioning to obtain a lower, more accurate value (best Ppao). The error due to partial occlusion, defined as the difference between the partial Ppao and the best Ppao, was 13 +/- 5 mm Hg (range, 6-21 mm Hg). The previously widened Ppad - Ppao gradient invariably narrowed during partial occlusion and then increased by 13 +/- 5 mm Hg (range, 5-23) during the best Ppao measurement. There was a moderate correlation between the error due to partial occlusion (partial Ppao - best Ppao) and both the mean pulmonary artery pressure (r =.77, <.01) and the Ppad - Ppao gradient (r =.79, <.01).
CONCLUSIONS: Partial occlusion in patients with pulmonary hypertension may lead to significant overestimation of the Ppao and should be suspected when there is a substantial increase in the Ppao without a concomitant increase in the Ppad, as reflected by a marked narrowing of a previously widened Ppad - Ppao gradient.

Entities:  

Mesh:

Year:  2003        PMID: 12545000     DOI: 10.1097/00003246-200301000-00015

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  5 in total

Review 1.  Continuous and less invasive central hemodynamic monitoring by blood pressure waveform analysis.

Authors:  Ramakrishna Mukkamala; Da Xu
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-07-09       Impact factor: 4.733

2.  Variability in hemodynamic evaluation of pulmonary hypertension at large referral centers.

Authors:  Meredith E Pugh; Anna R Hemnes; Aaron Trammell; John H Newman; Ivan M Robbins
Journal:  Pulm Circ       Date:  2014-12       Impact factor: 3.017

3.  Effect of balloon inflation volume on pulmonary artery occlusion pressure in patients with and without pulmonary hypertension.

Authors:  Adriano R Tonelli; Kamal K Mubarak; Ning Li; Robin Carrie; Hassan Alnuaimat
Journal:  Chest       Date:  2010-07-01       Impact factor: 9.410

4.  Continuous cardiac output and left atrial pressure monitoring by long time interval analysis of the pulmonary artery pressure waveform: proof of concept in dogs.

Authors:  Da Xu; N Bari Olivier; Ramakrishna Mukkamala
Journal:  J Appl Physiol (1985)       Date:  2008-12-04

5.  Diastolic Dysfunction Increases the Risk of Primary Graft Dysfunction after Lung Transplant.

Authors:  Mary K Porteous; Bonnie Ky; James N Kirkpatrick; Russell Shinohara; Joshua M Diamond; Rupal J Shah; James C Lee; Jason D Christie; Steven M Kawut
Journal:  Am J Respir Crit Care Med       Date:  2016-06-15       Impact factor: 21.405

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.