Literature DB >> 12543568

Intra-operative assessment of technical defects after carotid endarterectomy: a comparison between angiography and colour duplex scan.

D Valenti1, A Gaggiano, G Berardi, M Ferri, R Mazzei, G Roda, D Palombo.   

Abstract

We compared the intra-operative diagnostic value of CDS vs IA-DSA in identifying major and minor technical defects after CEA. Between August 1997 and December 1998, 138 consecutive patients undergoing 141 carotid endarterectomies were intra-operatively investigated with colour duplex scan and intra-arterial digital subtraction angiography. Thirty-six (25.5%) technical defects were identified. Four (11.1%) major defects were detected by both methods and they were immediately corrected. Fifteen (41.6%) minor defects were detected by both methods, thirteen (36.1%) minor defects were detected by colour duplex but ignored by angiography. Angiography detected four (11.1%) kinkings missed with the colour duplex. The overall sensitivity of both methods for major defect was 100%. The sensitivity of colour duplex for minor defects was 87% vs 59% for angiography. On the basis of our study, colour duplex could be considered the choice method for quality control after carotid endarterectomy.

Entities:  

Mesh:

Year:  2003        PMID: 12543568     DOI: 10.1016/s0967-2109(02)00112-6

Source DB:  PubMed          Journal:  Cardiovasc Surg        ISSN: 0967-2109


  1 in total

1.  [Intraoperative angiography in carotid artery reconstruction-Pathological findings, reliability and importance of the procedure].

Authors:  Jasmin Dillner; Frank Meyer; Zuhir Halloul; Michael Görtler
Journal:  Chirurg       Date:  2021-04-14       Impact factor: 0.955

  1 in total