Literature DB >> 12543507

High-performance liquid-chromatographic determination of warfarin enantiomers in plasma with automated on-line sample enrichment.

Venkata K Boppana1, William H Schaefer, Matthew J Cyronak.   

Abstract

A sensitive and selective chiral high performance liquid chromatographic method was developed for the direct determination of R- and S-warfarin enantiomers in human plasma. The method involved direct injection of human plasma onto a semipermeable surface (SPS) guard column, washing the proteins from the column with aqueous acetonitrile and back flushing the analytes onto a reversed phase ovomucoid silica HPLC column using switching valves. After separation, the analytes were simultaneously detected and quantitated with a fluorometer. The recoveries of R-warfarin from human plasma at 25 and 2500 ng/ml were 98.9% and 88.1%, respectively. The recoveries of S-warfarin at 25 and 2500 ng/ml were 105.4% and 93.9%, respectively. Using 100 microl of human plasma, the lower limit of quantification for both R- and S-warfarins was 25 ng/ml. Linear responses in analyte/internal standard peak height ratios were observed for analyte concentrations ranging from 25 to 2500 ng/ml for both enantiomers. Fluorescence chromatograms of drug-free human plasma showed no interfering peaks with retention times similar to those for R- and S-warfarins and the internal standard. Results from a 3-day validation study for both enantiomers demonstrated excellent precision (1.7-9.0%) and accuracy (97-109%) across the calibration range. Copyright 2002 Elsevier Science B.V.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12543507     DOI: 10.1016/s0165-022x(02)00122-7

Source DB:  PubMed          Journal:  J Biochem Biophys Methods        ISSN: 0165-022X


  3 in total

Review 1.  Comparative pharmacokinetics of vitamin K antagonists: warfarin, phenprocoumon and acenocoumarol.

Authors:  Mike Ufer
Journal:  Clin Pharmacokinet       Date:  2005       Impact factor: 6.447

2.  Quantification of Warfarin in Dried Rat Plasma Spots by High-Performance Liquid Chromatography with Tandem Mass Spectrometry.

Authors:  Alexander Chernonosov
Journal:  J Pharm (Cairo)       Date:  2016-12-12

3.  Validation of warfarin enantiomer analysis method in plasma using high-performance liquid chromatography fluorescence detector.

Authors:  Norisca Aliza Putriana; Taofik Rusdiana; Tina Rostinawati; Mohammad Rizki Akbar; Febrina Amelia Saputri; Siti Utami
Journal:  J Adv Pharm Technol Res       Date:  2022-01-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.