Effect of slow-curing on cavity wall adaptation using a new intensity-changeable light source.

Shigeru Uno1, Toru Tanaka, Asuka Natsuizaka, Tomoko Abo.   

Abstract

OBJECTIVE: The purpose of the study was to investigate the effects of a new intensity-changeable light source Curetron 7 (CT-7) devised for the slow-curing on cavity wall adaptation in the adhesive composite restorations, as well as the microhardness of the cured composite.
METHODS: Microhardness of both top and bottom surfaces was measured by an indentation method for 2mm thick cylindrical specimens, and cavity adaptation was evaluated in cylindrical dentin cavities (slashed circle 3.5x1.5mm(2)) of human extracted molars bonded to a hybrid resin composite. The irradiation was done with CT-7, VIP or Candelux (CDX) under the following five conditions: CT1, 600mW/cm(2)x30s (CT-7); CT2, 230mW/cm(2)x20s+600mW/cm(2)x20s (CT-7); CT3, 230mW/cm(2)x20s+pause x 10s+600mW/cm(2)x20s (CT-7); VIP, 300mW/cm(2)x3s+pause x 3min+600mW/cm(2)x30s (VIP); CDX, 200mW/cm(2)x10s+600mW/cm(2)x30s.
RESULTS: Five irradiation conditions had no influence on the microhardness for either top or bottom surface (Scheffe, p>0.05). In conditions CT3, VIP and CDX, top surfaces were harder than bottom surfaces (Student's t-test, p<0.05). The statistical analysis revealed no difference in adaptation among the locations along the cavity walls for each irradiation conditions (Kruskal-Wallis, p>0.05). In comparison of poled data for each condition, the best adaptation was seen in condition CT3, and the second in condition VIP (Kruskal-Wallis, p<0.05). SIGNIFICANCE: These results proved the efficacy of the slow-curing method combined with the interval between two irradiations with low intensity and high intensity. CT-7 could be useful for the adhesive composite restorations.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12543120     DOI: 10.1016/s0109-5641(02)00023-4

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  2 in total

1.  Effects of different light curing units/modes on the microleakage of flowable composite resins.

Authors:  A Ruya Yazici; Cigdem Celik; Berrin Dayangac; Gul Ozgunaltay
Journal:  Eur J Dent       Date:  2008-10

2.  Influence of different restorative techniques on marginal seal of class II composite restorations.

Authors:  Sinval Adalberto Rodrigues Junior; Lúcio Fernando da Silva Pin; Giovanna Machado; Alvaro Della Bona; Flávio Fernando Demarco
Journal:  J Appl Oral Sci       Date:  2010 Jan-Feb       Impact factor: 2.698

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.