Literature DB >> 12541231

Variation correction algorithm: analysis of phase suppression and thermal profile fidelity for proton resonance frequency magnetic resonance thermometry at 0.2 T.

Kestutis J Barkauskas1, Jonathan S Lewin, Jeffrey L Duerk.   

Abstract

PURPOSE: To develop and analyze the performance of the variation correction algorithm (VCA), a phase correction technique that mitigates the contribution of background phase variations by combining accurate alignment of echoes, K-space-based phase correction (as opposed to spatial polynomials), and extraction of alias-free phase difference images.
MATERIALS AND METHODS: A series of echo-shifted gradient-recalled echo (GRE) images was processed with K-space alignment and phase corrected with increasing sizes of M x M masks of central K-space coefficients. The extent of background phase variation suppression due to magnet field drift was assessed. Further, a simulated thermal profile was superimposed on the same data in a related experiment. Residual errors in reconstructed simulated thermal profiles were quantitatively characterized to estimate algorithm performance.
RESULTS: Using a 3 x 3 K-space mask, the VCA was able to 1) maintain the typical mean background error in a 35 x 35 pixel region of interest (ROI) at -0.1 degrees C; and 2) reconstruct, relative to the applied thermal profile, a phase-corrected profile that typically contains a 1.7 degrees C underestimation of peak temperature difference and a mean error along the 60 degrees C line of -0.8 degrees C.
CONCLUSION: The results suggest that thermal profiles can be accurately reconstructed at 0.2 T using the VCA, even in the presence of over 1 ppm spatially and temporally dependent field drift over a 1-hour time frame. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12541231     DOI: 10.1002/jmri.10239

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  5 in total

1.  MRI of frozen tissue demonstrates a phase shift.

Authors:  Aiming Lu; Bruce L Daniel; Elena Kaye; Kim Butts Pauly
Journal:  Magn Reson Med       Date:  2011-05-31       Impact factor: 4.668

2.  Monitoring and correcting spatio-temporal variations of the MR scanner's static magnetic field.

Authors:  AbdEl Monem El-Sharkawy; Michael Schär; Paul A Bottomley; Ergin Atalar
Journal:  MAGMA       Date:  2006-10-17       Impact factor: 2.310

3.  Assessment of thermal effects of interstitial laser phototherapy on mammary tumors using proton resonance frequency method.

Authors:  Kelvin Le; Xiaosong Li; Daniel Figueroa; Rheal A Towner; Philippe Garteiser; Debra Saunders; Nataliya Smith; Hong Liu; Tomas Hode; Robert E Nordquist; Wei R Chen
Journal:  J Biomed Opt       Date:  2011-12       Impact factor: 3.170

4.  Drift correction for accurate PRF-shift MR thermometry during mild hyperthermia treatments with MR-HIFU.

Authors:  Chenchen Bing; Robert M Staruch; Matti Tillander; Max O Köhler; Charles Mougenot; Mika Ylihautala; Theodore W Laetsch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2016-05-22       Impact factor: 3.914

5.  Comprehensive multiphase NMR applied to a living organism.

Authors:  Yalda Liaghati Mobarhan; Blythe Fortier-McGill; Ronald Soong; Werner E Maas; Michael Fey; Martine Monette; Henry J Stronks; Sebastian Schmidt; Hermann Heumann; Warren Norwood; André J Simpson
Journal:  Chem Sci       Date:  2016-04-18       Impact factor: 9.825

  5 in total