Literature DB >> 12539189

Mass calibration of a matrix-assisted laser desorption/ionization time-of-flight mass spectrometer including the rise time of the delayed extraction pulse.

E Moskovets1, B L Karger.   

Abstract

To utilize fully modern MALDI-TOF and TOF/TOF mass spectrometers with mass resolution exceeding 10,000 and 2 ppm precision of flight time measurements for high mass accuracy, the model of ion motion used in the mass calibration equation must be expanded. The standard three-term equation providing up to 5-10 ppm (rms) mass accuracy with internal standards was modified with an additional term accounting for the finite rise time of the high-voltage extraction pulse. This new four-term calibration equation minimizes the effect of systematic error resulting from the fact that ion velocities are mass dependent due to the rise time of the extraction pulse. Applying this new calibration equation to a mass spectrum obtained in an axial MALDI-TOF MS containing 70 peaks (sodiated PEG), each with a signal-to-noise ratio greater than 100, a mass accuracy of 1.6 ppm (rms) was obtained over the mass range 1.0-4.0 kDa compared with 3.6 ppm (rms) with the standard three-term equation. The physical basis of the effects of the finite extraction pulse rise time on mass calibration is examined for axial MALDI-TOF mass spectrometers, as well as for orthogonal acceleration TOF mass spectrometers. Copyright 2002 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2003        PMID: 12539189     DOI: 10.1002/rcm.898

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

1.  Generation of CsI cluster ions for mass calibration in matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  Xianwen Lou; Joost L J van Dongen; E W Meijer
Journal:  J Am Soc Mass Spectrom       Date:  2010-03-31       Impact factor: 3.109

2.  Mass shift in mass spectrometry imaging: comprehensive analysis and practical corrective workflow.

Authors:  Andréa McCann; Sophie Rappe; Raphaël La Rocca; Mathieu Tiquet; Loïc Quinton; Gauthier Eppe; Johann Far; Edwin De Pauw; Christopher Kune
Journal:  Anal Bioanal Chem       Date:  2021-01-30       Impact factor: 4.142

3.  Removal of optimal cutting temperature (O.C.T.) compound from embedded tissue for MALDI imaging of lipids.

Authors:  Jacob X M Truong; Xander Spotbeen; Jake White; Johannes V Swinnen; Lisa M Butler; Marten F Snel; Paul J Trim
Journal:  Anal Bioanal Chem       Date:  2021-02-09       Impact factor: 4.142

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.