Literature DB >> 12539104

Fiducial segment averaging to improve cardiac time interval estimates.

H J Ritsema van Eck1.   

Abstract

To improve the accuracy of fiducial point estimates, a technique was developed and tested that uses the coherence of relatively small segments within the P-QRS-T complex from beat to beat. The methodology is applied to digitally stored electrocardiogram traces from various sources. It can be applied to single or multiple leads. First, the individual QRS complexes are identified with a matched filter technique. The trigger time points obtained are fine-adjusted by cross-correlating in turn each individual complex with the average of the remainder complexes and then shifting the complex till maximum correlation is achieved. The process is repeated till no improvement can be attained. Then the individual fiducial points are identified and a similar fine-adjustment is made to the individual points with a segment of approximately 60 ms around the fiducial point. This process is performed in turn for P-onset, QRS-onset and offset, peak of T wave and end of T wave. The values of PR-interval, QRS-duration and QT follow from these measurements. The validity of the result can be assessed by visual inspection and by examining the standard deviation of the measurements obtained. From the above intervals, it is generally accepted that QRS-duration is fairly constant over a short recording duration, whereas PR and QT are inherently heart-rate dependent. Often a linear regression of QT onto RR can be calculated with a significant correlation coefficient, indicating a physiological QT/RR relationship in these recordings of relative short duration. It would be impossible to show this last relationship if the individual QT changes had not been preserved by the technique described.

Mesh:

Year:  2002        PMID: 12539104     DOI: 10.1054/jelc.2002.37160

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  7 in total

1.  QT interval variability in body surface ECG: measurement, physiological basis, and clinical value: position statement and consensus guidance endorsed by the European Heart Rhythm Association jointly with the ESC Working Group on Cardiac Cellular Electrophysiology.

Authors:  Mathias Baumert; Alberto Porta; Marc A Vos; Marek Malik; Jean-Philippe Couderc; Pablo Laguna; Gianfranco Piccirillo; Godfrey L Smith; Larisa G Tereshchenko; Paul G A Volders
Journal:  Europace       Date:  2016-01-27       Impact factor: 5.214

2.  Circadian pattern of short-term variability of the QT-interval in primary prevention ICD patients - EU-CERT-ICD methodological pilot study.

Authors:  David J Sprenkeler; Anton E Tuinenburg; Henk J Ritsema van Eck; Marek Malik; Markus Zabel; Marc A Vos
Journal:  PLoS One       Date:  2017-08-21       Impact factor: 3.240

3.  Validation of automatic measurement of QT interval variability.

Authors:  Peter R Rijnbeek; Marten E van den Berg; Gerard van Herpen; Henk J Ritsema van Eck; Jan A Kors
Journal:  PLoS One       Date:  2017-04-12       Impact factor: 3.240

4.  Normal Values of QT Variability in 10-s Electrocardiograms for all Ages.

Authors:  Marten E van den Berg; Jan A Kors; Gerard van Herpen; Michiel L Bots; Hans Hillege; Cees A Swenne; Bruno H Stricker; Peter R Rijnbeek
Journal:  Front Physiol       Date:  2019-10-04       Impact factor: 4.566

5.  Evaluation of biomarkers for cardiotoxicity of anthracyclin-based chemotherapy.

Authors:  F J F Broeyer; S Osanto; H J Ritsema van Eck; A Q M J van Steijn; B E P B Ballieux; R C Schoemaker; A F Cohen; J Burggraaf
Journal:  J Cancer Res Clin Oncol       Date:  2008-03-15       Impact factor: 4.553

6.  The development and validation of an easy to use automatic QT-interval algorithm.

Authors:  Ben J M Hermans; Arja S Vink; Frank C Bennis; Luc H Filippini; Veronique M F Meijborg; Arthur A M Wilde; Laurent Pison; Pieter G Postema; Tammo Delhaas
Journal:  PLoS One       Date:  2017-09-01       Impact factor: 3.240

7.  Short-Term Variability of the QT Interval Can be Used for the Prediction of Imminent Ventricular Arrhythmias in Patients With Primary Prophylactic Implantable Cardioverter Defibrillators.

Authors:  Agnieszka Smoczyńska; Vera Loen; David J Sprenkeler; Anton E Tuinenburg; Henk J Ritsema van Eck; Marek Malik; Georg Schmidt; Mathias Meine; Marc A Vos
Journal:  J Am Heart Assoc       Date:  2020-11-20       Impact factor: 5.501