Comparability of 12-lead ECGs derived from EASI leads with standard 12-lead ECGS in the classification of acute myocardial ischemia and old myocardial infarction.

Pentti M Rautaharju1, Sophia H Zhou, E William Hancock, B Milan Horácek, Dirk Q Feild, James M Lindauer, Galen S Wagner, Olle Pahlm, Charles L Feldman.   

Abstract

We compared 12-lead electrocardiograms (ECGs) derived with an improved transformation matrix from EASI leads and standard 12-lead ECGs in the detection of acute myocardial ischemia and old infarction (MI). For the ischemia test, we used ECGs of 40 patients recorded prior to and at peak inflation during percutaneous transluminal coronary angioplasty, and for old MI we used test ECGs of 382 non-MI subjects and of 472 patients with prior MI documented by enzyme findings. Two experienced ECG readers served as separate, independent standards for lead-set comparisons, and the Philips ECG analysis program also classified the ECGs. The results showed no significant differences between the two lead sets in the detection of acute inflation-induced ischemia or of old MI according to coding by the electrocardiographers or the computer program. No significant differences were found between the electrocardiographers and the lead sets for acute ischemia. Classification differences between the electrocardiographers were larger than those between the lead sets for acute and old MI and were significant for the latter (P <.001). A more detailed comparison of the lead sets suggested a possible need for modified old-MI criteria and optimization of ST classification thresholds for acute ischemic injury, specific for the EASI 12-lead ECG. We conclude that the EASI-derived 12-lead ECG deserves serious consideration as an alternative to the standard 12-lead ECG in emergency situations and for monitoring in acute-care setting.

Entities:  

Mesh:

Year:  2002        PMID: 12539097     DOI: 10.1054/jelc.2002.37152

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  4 in total

Review 1.  Technical mistakes during the acquisition of the electrocardiogram.

Authors:  Javier García-Niebla; Pablo Llontop-García; Juan Ignacio Valle-Racero; Guillem Serra-Autonell; Velislav N Batchvarov; Antonio Bayés de Luna
Journal:  Ann Noninvasive Electrocardiol       Date:  2009-10       Impact factor: 1.468

2.  The prognostic significance of frequency and morphology of premature ventricular complexes during ambulatory holter monitoring.

Authors:  Georges Ephrem; Michael Levine; Patricia Friedmann; Paul Schweitzer
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-11-22       Impact factor: 1.468

Review 3.  12-lead Holter electrocardiography. Review of the literature and clinical application update.

Authors:  Li Su; Stefan Borov; Bernhard Zrenner
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-06-19

4.  Feasibility of CardioSecur®, a Mobile 4-Electrode/22-Lead ECG Device, in the Prehospital Emergency Setting.

Authors:  Sebastian Spaich; Hanna Kern; Thomas A Zelniker; Jan Stiepak; Michael Gabel; Erik Popp; Hugo A Katus; Michael R Preusch
Journal:  Front Cardiovasc Med       Date:  2020-10-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.