False aneurysm due to suture loosening after aortic arch replacement.

Keita Tanaka1, Haruo Makuuchi, Yoshihiro Naruse, Toshiya Kobayashi, Ichiro Hayashi, Takehiko Takayama, Yusuke Namifusa.   

Abstract

We describe a case of false aneurysm due to loosening of the anastomotic sutures 5 years after graft replacement for subacute type A aortic dissection. Leakage from the graft was controlled by tightening the suture slack indicating that suture loosening was the cause of the aneurysm. The mechanism was probably the progressive thinning of the edematous swollen aortic wall over the years causing the sutures to loosen.

Entities:  

Mesh:

Year:  2002        PMID: 12538285     DOI: 10.1177/021849230201000417

Source DB:  PubMed          Journal:  Asian Cardiovasc Thorac Ann        ISSN: 0218-4923


  1 in total

1.  Pseudoaneurysm due to stentgraft-graft anastomosis failure: A case report.

Authors:  Yuki Wada; Kazuhisa Sakamoto; Akira Marui; Nobuhisa Ohno
Journal:  JTCVS Tech       Date:  2022-05-29