| Literature DB >> 12537314 |
Hugo Devlieger1, Thierry Bayet, Jacques Lombet, Stéphane Naudé, Christian Eugène.
Abstract
Most modern neonatal ventilators have now a built-in flow sensor and, as a spin-off of their mechanical action, provide some information about lung function characteristics as compliance and resistance after computation of the flow and pressure signals. Additionally, respiratory graphics as volume-pressure and flow-volume plots can be displayed. In clinical practice, however, they are rarely used to refine the ventilator setting. A nonconventional flow-pressure plot is presented in this article, constructed from the volume or flow, and pressure outputs of a Babylog 8000 (Dräger, Lübeck, Germany). This flow-pressure diagram appears to be useful in the real-time computation of respiratory mechanics based on the Rahn's law of respiratory motion. Its major advantage, however, is the easy pattern recognition of subtle changes in infant-ventilator interaction, ie, excessive triggering, fighting against the ventilator, augmented breath, tube subobstruction. It may be useful to add the flow-pressure plot to the classical respiratory graphics allowing to monitor mechanical ventilation more accurately and to fine tune the ventilator setting accordingly.Entities:
Mesh:
Year: 2002 PMID: 12537314 DOI: 10.1053/sper.2002.37316
Source DB: PubMed Journal: Semin Perinatol ISSN: 0146-0005 Impact factor: 3.300